MP-ETC Series-5225
The China Moneypro ETC Series is a high‑capacity three‑phase hybrid energy storage inverter designed for commercial and industrial solar + storage systems. It supports a wide battery voltage range and advanced modular design for flexible installation, robust grid support, and reliable backup power operation.
High‑Power, Flexible & Reliable Commercial Energy Storage
The China Moneypro ETC Series is a high‑capacity three‑phase hybrid energy storage inverter designed for commercial and industrial solar + storage systems. It supports a wide battery voltage range and advanced modular design for flexible installation, robust grid support, and reliable backup power operation.
Powerful Hybrid Performance
Modular & Flexible Architecture
-
Designed with a Plug & Play modular architecture featuring MPPT, DC/DC, DC/AC, STS, and EMS modules to simplify installation and system expansion.
-
Compatible with a wide battery voltage range (200 V to 865 V) for greater flexibility in battery selection and sizing.
Benefits:
-
Faster commissioning and reduced onsite complexity.
-
Easy adaptation to different storage system designs and capacities.
Seamless Backup & Grid Support
UPS‑Level Switching & Reliable Supply
-
UPS‑level switching in < 10 ms ensures uninterrupted power to critical loads when grid faults occur.
-
Supports 100 % unbalanced output and up to 110 % continuous AC overload capacity under backup mode — ideal for peak load and transient demand handling.
-
Integrated Type II SPD (surge protection device) improves electrical safety and protects against voltage spikes.
Advantages:
-
High reliability during grid outages or transient conditions.
-
Strong support for industrial and critical loads.
Intelligent Energy Management
Enhanced Efficiency & Application Flexibility
-
Unbalanced AC output and adjustable power parameters increase load flexibility and system utilization.
-
Suitable for peak shaving, self‑consumption optimization, and robust backup power scenarios — lowering energy costs and improving grid stability.
-
Designed for commercial and industrial energy storage projects where high performance and operational flexibility are essential.
Benefits:
-
Greater operational control for C&I (commercial & industrial) systems.
-
Efficient integration with solar PV and battery systems for energy cost optimization.
Why Choose China Moneypro ETC Series?
-
High‑Capacity Hybrid Inverter: Robust three‑phase power output suitable for large‑scale storage installations.
-
Wide Battery Compatibility: Supports 200 V to 865 V range for flexible battery system integration.
-
Fast UPS Switching: < 10 ms transfer to backup power ensures critical load continuity.
-
Modular & Easy Installation: Plug & Play modular design simplifies system setup and maintenance.
-
Advanced Protection: Built‑in Type II SPD and high overload tolerance ensure safe operation in challenging environments.
Typical Applications
-
Commercial Solar + Storage: Peak shaving, energy management, and demand charge reduction for business rooftops, factories and facilities.
-
Industrial Facilities: Reliable power support and grid services for large electrical loads.
-
Backup Power Systems: Uninterrupted power supply for critical infrastructure.
-
Energy Cost Optimization: Self‑consumption maximization and grid energy cost reduction.
FAQ – Common Questions
Q1: What battery voltage range does the ETC Series support?
The series supports a wide battery voltage range from 200 V to 865 V, allowing compatibility with a broad set of HV battery systems.
Q2: How fast does the system switch to backup power?
The ETC Series provides UPS‑level switching in less than 10 ms, ensuring critical loads remain powered during grid faults.
Q3: Can the inverter handle overload conditions?
Yes — it supports 110 % continuous AC overload capacity in backup mode for stable power delivery during peak demand.
Q4: Is the system suitable for unbalanced three‑phase loads?
Yes — the ETC Series supports 100 % unbalanced output, improving flexibility for three‑phase load distribution.
Q5: What applications is this inverter best suited for?
It is ideal for commercial and industrial energy storage, peak load management, and robust backup applications that require high performance and flexible system integration.
Specifications
| Parameter | GW50K07‑ETC | GW50K06‑ETC | GW100K07‑ETC | GW100K06‑ETC |
|---|---|---|---|---|
| Battery Input Data | ||||
| Battery Type | Li‑Ion | Li‑Ion | Li‑Ion | Li‑Ion |
| Nominal Battery Voltage (V) | 422.4 / 499.2 / 576.0 / 652.8 | 422.4 / 499.2 / 576.0 / 652.8 | 422.4 / 499.2 / 576.0 / 652.8 | 422.4 / 499.2 / 576.0 / 652.8 |
| Battery Voltage Range (V) | 200 ~ 865 | 200 ~ 865 | 200 ~ 865 | 200 ~ 865 |
| Start‑up Voltage (V) | 200 | 200 | 200 | 200 |
| Number of Battery Input | 1 | 1 | 2 | 2 |
| Max. Continuous Charging Current (A) | 100 | 100 | 100 / 100 | 100 / 100 |
| Max. Continuous Discharging Current (A) | 100 | 100 | 100 / 100 | 100 / 100 |
| Max. Charging Power (kW) | 50 | 50 | 100 | 100 |
| Max. Discharging Power (kW) | 55 | 55 | 110 | 110 |
| PV String Input Data | ||||
| Max. Input Power (kW) | 65 | 65 | 130 | 130 |
| Max. Input Voltage (V) | 1000 | 1000 | 1000 | 1000 |
| MPPT Operating Voltage Range (V) | 250 ~ 960 | 250 ~ 960 | 250 ~ 960 | 250 ~ 960 |
| Start‑up Voltage (V) | 250 | 250 | 250 | 250 |
| Nominal Input Voltage (V) | 600 | 600 | 600 | 600 |
| Max. Input Current per MPPT (A) | 100 | 100 | 100 | 100 |
| Max. Short Circuit Current per MPPT (A) | 125 | 125 | 125 | 125 |
| Number of MPP Trackers | 1 | 1 | 2 | 2 |
| AC Output Data (On‑grid) | ||||
| Nominal Output Power (kW) | 50 | 50 | 100 | 100 |
| Nominal Apparent Power Output to Utility Grid (kVA) | 50 | 50 | 100 | 100 |
| Max. Apparent Power Output to Utility Grid (kVA) | 55 | 55 | 110 | 110 |
| Max. Apparent Power from Utility Grid (kVA) | 55 | 55 | 110 | 110 |
| Nominal Output Voltage (V) | 400, 3L / N / PE | 400, 3L / N / PE | 400, 3L / N / PE | 400, 3L / N / PE |
| Output Voltage Range (V) | 312 ~ 460 (AU); 318 ~ 497 (Germany) | 312 ~ 460 (AU); 318 ~ 497 (Germany) | 312 ~ 460 (AU); 318 ~ 497 (Germany) | 312 ~ 460 (AU); 318 ~ 497 (Germany) |
| Nominal AC Grid Frequency (Hz) | 50 / 60 | 50 / 60 | 50 / 60 | 50 / 60 |
| AC Grid Frequency Range (Hz) | 47 ~ 52 (AU); 47.5 ~ 51.5 (Germany) | 47 ~ 52 (AU); 47.5 ~ 51.5 (Germany) | 47 ~ 52 (AU); 47.5 ~ 51.5 (Germany) | 47 ~ 52 (AU); 47.5 ~ 51.5 (Germany) |
| Max. AC Current Output to Utility Grid (A) | 79.8 | 79.8 | 159.5 | 159.5 |
| Max. AC Current from Utility Grid (A) | 79.8 | 79.8 | 159.5 | 159.5 |
| Power Factor | ~1 (Adjustable from 0.8 leading to 0.8 lagging) | ~1 (Adjustable from 0.8 leading to 0.8 lagging) | ~1 (Adjustable from 0.8 leading to 0.8 lagging) | ~1 (Adjustable from 0.8 leading to 0.8 lagging) |
| Max. Total Harmonic Distortion | <3% | <3% | <3% | <3% |
| AC Output Data (Back‑up) | ||||
| Back‑up Nominal Apparent Power (kVA) | 50 | – | 100 | – |
| Max. Output Apparent Power without Grid (kVA) | 55 | – | 110 | – |
| Max. Output Apparent Power with Grid (kVA) | 55 | – | 110 | – |
| Max. Output Current (A) | 79.8 | – | 159.5 | – |
| Nominal Output Voltage (V) | 400 | – | 400 | – |
| Nominal Output Frequency (Hz) | 50 / 60 | – | 50 / 60 | – |
| Output THDv (@ Linear Load) | <3% | – | <3% | – |
| EFFICIENCY | ||||
| Max. Efficiency | 97.6% | 97.6% | 97.6% | 97.6% |
| European Efficiency | 97.3% | 97.3% | 97.3% | 97.3% |
| Max. Battery to AC Efficiency | 97.2% | 97.2% | 97.2% | 97.2% |
| MPPT Efficiency | 99.9% | 99.9% | 99.9% | 99.9% |
| Protection | ||||
| PV Insulation Resistance Detection | Integrated | Integrated | Integrated | Integrated |
| Residual Current Monitoring | Integrated | Integrated | Integrated | Integrated |
| PV Reverse Polarity Protection | Integrated | Integrated | Integrated | Integrated |
| Battery Reverse Polarity Protection | Integrated | Integrated | Integrated | Integrated |
| Anti‑islanding Protection | Integrated | Integrated | Integrated | Integrated |
| AC Overcurrent Protection | Integrated | Integrated | Integrated | Integrated |
| AC Short Circuit Protection | Integrated | Integrated | Integrated | Integrated |
| AC Overvoltage Protection | Integrated | Integrated | Integrated | Integrated |
| DC Switch | Integrated | Integrated | Integrated | Integrated |
| AC Switch | Integrated | Integrated | Integrated | Integrated |
| DC Surge Protection | Type II (Type I + II Optional) | Type II (Type I + II Optional) | Type II (Type I + II Optional) | Type II (Type I + II Optional) |
| AC Surge Protection | Type II (Type I + II Optional) | Type II (Type I + II Optional) | Type II (Type I + II Optional) | Type II (Type I + II Optional) |
| Emergency Power Off | Integrated | Integrated | Integrated | Integrated |
| Remote Shutdown | Integrated | Integrated | Integrated | Integrated |
| General Data | ||||
| Operating Temperature Range (°C) | -20 ~ +60 ( >45°C derating ) | -20 ~ +60 ( >45°C derating ) | -20 ~ +60 ( >45°C derating ) | -20 ~ +60 ( >45°C derating ) |
| Relative Humidity | 0 ~ 95% (Non‑condensing) | 0 ~ 95% (Non‑condensing) | 0 ~ 95% (Non‑condensing) | 0 ~ 95% (Non‑condensing) |
| Max. Operating Altitude (m) | 4000 | 4000 | 4000 | 4000 |
| Cooling Method | Smart Fan Cooling | Smart Fan Cooling | Smart Fan Cooling | Smart Fan Cooling |
| User Interface | LED, LCD, WLAN + APP | LED, LCD, WLAN + APP | LED, LCD, WLAN + APP | LED, LCD, WLAN + APP |
| Communication with BMS | RS485, CAN | RS485, CAN | RS485, CAN | RS485, CAN |
| Communication with Meter | RS485 | RS485 | RS485 | RS485 |
| Communication with Portal | RS485, LAN | RS485, LAN | RS485, LAN | RS485, LAN |
| Weight (kg) | 184.5 | 170.0 | 239.5 | 225.0 |
| Dimension (W × H × D mm) | 585 × 1360 × 750 | 585 × 1360 × 750 | 585 × 1360 × 750 | 585 × 1360 × 750 |
| Noise Emission (dB) | <68 | <68 | <68 | <68 |
| Topology | Non‑isolated | Non‑isolated | Non‑isolated | Non‑isolated |
| Ingress Protection Rating | IP20 | IP20 | IP20 | IP20 |
| Mounting Method | Grounded | Grounded | Grounded | Grounded |