The China Moneypro ETC Series is a high‑capacity three‑phase hybrid energy storage inverter designed for commercial and industrial solar + storage systems. It supports a wide battery voltage range and advanced modular design for flexible installation, robust grid support, and reliable backup power operation.

Share your love

High‑Power, Flexible & Reliable Commercial Energy Storage

The China Moneypro ETC Series is a high‑capacity three‑phase hybrid energy storage inverter designed for commercial and industrial solar + storage systems. It supports a wide battery voltage range and advanced modular design for flexible installation, robust grid support, and reliable backup power operation.


Powerful Hybrid Performance

Modular & Flexible Architecture

  • Designed with a Plug & Play modular architecture featuring MPPT, DC/DC, DC/AC, STS, and EMS modules to simplify installation and system expansion.

  • Compatible with a wide battery voltage range (200 V to 865 V) for greater flexibility in battery selection and sizing.

Benefits:

  • Faster commissioning and reduced onsite complexity.

  • Easy adaptation to different storage system designs and capacities.


Seamless Backup & Grid Support

UPS‑Level Switching & Reliable Supply

  • UPS‑level switching in < 10 ms ensures uninterrupted power to critical loads when grid faults occur.

  • Supports 100 % unbalanced output and up to 110 % continuous AC overload capacity under backup mode — ideal for peak load and transient demand handling.

  • Integrated Type II SPD (surge protection device) improves electrical safety and protects against voltage spikes.

Advantages:

  • High reliability during grid outages or transient conditions.

  • Strong support for industrial and critical loads.


Intelligent Energy Management

Enhanced Efficiency & Application Flexibility

  • Unbalanced AC output and adjustable power parameters increase load flexibility and system utilization.

  • Suitable for peak shaving, self‑consumption optimization, and robust backup power scenarios — lowering energy costs and improving grid stability.

  • Designed for commercial and industrial energy storage projects where high performance and operational flexibility are essential.

Benefits:

  • Greater operational control for C&I (commercial & industrial) systems.

  • Efficient integration with solar PV and battery systems for energy cost optimization.


Why Choose China Moneypro ETC Series?

  • High‑Capacity Hybrid Inverter: Robust three‑phase power output suitable for large‑scale storage installations.

  • Wide Battery Compatibility: Supports 200 V to 865 V range for flexible battery system integration.

  • Fast UPS Switching: < 10 ms transfer to backup power ensures critical load continuity.

  • Modular & Easy Installation: Plug & Play modular design simplifies system setup and maintenance.

  • Advanced Protection: Built‑in Type II SPD and high overload tolerance ensure safe operation in challenging environments.


Typical Applications

  • Commercial Solar + Storage: Peak shaving, energy management, and demand charge reduction for business rooftops, factories and facilities.

  • Industrial Facilities: Reliable power support and grid services for large electrical loads.

  • Backup Power Systems: Uninterrupted power supply for critical infrastructure.

  • Energy Cost Optimization: Self‑consumption maximization and grid energy cost reduction.


FAQ – Common Questions

Q1: What battery voltage range does the ETC Series support?
The series supports a wide battery voltage range from 200 V to 865 V, allowing compatibility with a broad set of HV battery systems.

Q2: How fast does the system switch to backup power?
The ETC Series provides UPS‑level switching in less than 10 ms, ensuring critical loads remain powered during grid faults.

Q3: Can the inverter handle overload conditions?
Yes — it supports 110 % continuous AC overload capacity in backup mode for stable power delivery during peak demand.

Q4: Is the system suitable for unbalanced three‑phase loads?
Yes — the ETC Series supports 100 % unbalanced output, improving flexibility for three‑phase load distribution.

Q5: What applications is this inverter best suited for?
It is ideal for commercial and industrial energy storage, peak load management, and robust backup applications that require high performance and flexible system integration.


Specifications

Parameter GW50K07‑ETC GW50K06‑ETC GW100K07‑ETC GW100K06‑ETC
Battery Input Data
Battery Type Li‑Ion Li‑Ion Li‑Ion Li‑Ion
Nominal Battery Voltage (V) 422.4 / 499.2 / 576.0 / 652.8 422.4 / 499.2 / 576.0 / 652.8 422.4 / 499.2 / 576.0 / 652.8 422.4 / 499.2 / 576.0 / 652.8
Battery Voltage Range (V) 200 ~ 865 200 ~ 865 200 ~ 865 200 ~ 865
Start‑up Voltage (V) 200 200 200 200
Number of Battery Input 1 1 2 2
Max. Continuous Charging Current (A) 100 100 100 / 100 100 / 100
Max. Continuous Discharging Current (A) 100 100 100 / 100 100 / 100
Max. Charging Power (kW) 50 50 100 100
Max. Discharging Power (kW) 55 55 110 110
PV String Input Data
Max. Input Power (kW) 65 65 130 130
Max. Input Voltage (V) 1000 1000 1000 1000
MPPT Operating Voltage Range (V) 250 ~ 960 250 ~ 960 250 ~ 960 250 ~ 960
Start‑up Voltage (V) 250 250 250 250
Nominal Input Voltage (V) 600 600 600 600
Max. Input Current per MPPT (A) 100 100 100 100
Max. Short Circuit Current per MPPT (A) 125 125 125 125
Number of MPP Trackers 1 1 2 2
AC Output Data (On‑grid)
Nominal Output Power (kW) 50 50 100 100
Nominal Apparent Power Output to Utility Grid (kVA) 50 50 100 100
Max. Apparent Power Output to Utility Grid (kVA) 55 55 110 110
Max. Apparent Power from Utility Grid (kVA) 55 55 110 110
Nominal Output Voltage (V) 400, 3L / N / PE 400, 3L / N / PE 400, 3L / N / PE 400, 3L / N / PE
Output Voltage Range (V) 312 ~ 460 (AU); 318 ~ 497 (Germany) 312 ~ 460 (AU); 318 ~ 497 (Germany) 312 ~ 460 (AU); 318 ~ 497 (Germany) 312 ~ 460 (AU); 318 ~ 497 (Germany)
Nominal AC Grid Frequency (Hz) 50 / 60 50 / 60 50 / 60 50 / 60
AC Grid Frequency Range (Hz) 47 ~ 52 (AU); 47.5 ~ 51.5 (Germany) 47 ~ 52 (AU); 47.5 ~ 51.5 (Germany) 47 ~ 52 (AU); 47.5 ~ 51.5 (Germany) 47 ~ 52 (AU); 47.5 ~ 51.5 (Germany)
Max. AC Current Output to Utility Grid (A) 79.8 79.8 159.5 159.5
Max. AC Current from Utility Grid (A) 79.8 79.8 159.5 159.5
Power Factor ~1 (Adjustable from 0.8 leading to 0.8 lagging) ~1 (Adjustable from 0.8 leading to 0.8 lagging) ~1 (Adjustable from 0.8 leading to 0.8 lagging) ~1 (Adjustable from 0.8 leading to 0.8 lagging)
Max. Total Harmonic Distortion <3% <3% <3% <3%
AC Output Data (Back‑up)
Back‑up Nominal Apparent Power (kVA) 50 100
Max. Output Apparent Power without Grid (kVA) 55 110
Max. Output Apparent Power with Grid (kVA) 55 110
Max. Output Current (A) 79.8 159.5
Nominal Output Voltage (V) 400 400
Nominal Output Frequency (Hz) 50 / 60 50 / 60
Output THDv (@ Linear Load) <3% <3%
EFFICIENCY
Max. Efficiency 97.6% 97.6% 97.6% 97.6%
European Efficiency 97.3% 97.3% 97.3% 97.3%
Max. Battery to AC Efficiency 97.2% 97.2% 97.2% 97.2%
MPPT Efficiency 99.9% 99.9% 99.9% 99.9%
Protection
PV Insulation Resistance Detection Integrated Integrated Integrated Integrated
Residual Current Monitoring Integrated Integrated Integrated Integrated
PV Reverse Polarity Protection Integrated Integrated Integrated Integrated
Battery Reverse Polarity Protection Integrated Integrated Integrated Integrated
Anti‑islanding Protection Integrated Integrated Integrated Integrated
AC Overcurrent Protection Integrated Integrated Integrated Integrated
AC Short Circuit Protection Integrated Integrated Integrated Integrated
AC Overvoltage Protection Integrated Integrated Integrated Integrated
DC Switch Integrated Integrated Integrated Integrated
AC Switch Integrated Integrated Integrated Integrated
DC Surge Protection Type II (Type I + II Optional) Type II (Type I + II Optional) Type II (Type I + II Optional) Type II (Type I + II Optional)
AC Surge Protection Type II (Type I + II Optional) Type II (Type I + II Optional) Type II (Type I + II Optional) Type II (Type I + II Optional)
Emergency Power Off Integrated Integrated Integrated Integrated
Remote Shutdown Integrated Integrated Integrated Integrated
General Data
Operating Temperature Range (°C) -20 ~ +60 ( >45°C derating ) -20 ~ +60 ( >45°C derating ) -20 ~ +60 ( >45°C derating ) -20 ~ +60 ( >45°C derating )
Relative Humidity 0 ~ 95% (Non‑condensing) 0 ~ 95% (Non‑condensing) 0 ~ 95% (Non‑condensing) 0 ~ 95% (Non‑condensing)
Max. Operating Altitude (m) 4000 4000 4000 4000
Cooling Method Smart Fan Cooling Smart Fan Cooling Smart Fan Cooling Smart Fan Cooling
User Interface LED, LCD, WLAN + APP LED, LCD, WLAN + APP LED, LCD, WLAN + APP LED, LCD, WLAN + APP
Communication with BMS RS485, CAN RS485, CAN RS485, CAN RS485, CAN
Communication with Meter RS485 RS485 RS485 RS485
Communication with Portal RS485, LAN RS485, LAN RS485, LAN RS485, LAN
Weight (kg) 184.5 170.0 239.5 225.0
Dimension (W × H × D mm) 585 × 1360 × 750 585 × 1360 × 750 585 × 1360 × 750 585 × 1360 × 750
Noise Emission (dB) <68 <68 <68 <68
Topology Non‑isolated Non‑isolated Non‑isolated Non‑isolated
Ingress Protection Rating IP20 IP20 IP20 IP20
Mounting Method Grounded Grounded Grounded Grounded