MP-ET Series-4913
The China Moneypro ET‑100 kW Series is a high‑power three‑phase hybrid inverter engineered for commercial and industrial (C&I) energy storage applications. Designed to deliver reliable grid support, enhanced energy harvest, intelligent operating modes, and robust backup performance, it provides an efficient foundation for solar‑plus‑storage systems in complex commercial environments.
Powerful, Flexible & Resilient C&I Storage Inverter
The China Moneypro ET‑100 kW Series is a high‑power three‑phase hybrid inverter engineered for commercial and industrial (C&I) energy storage applications. Designed to deliver reliable grid support, enhanced energy harvest, intelligent operating modes, and robust backup performance, it provides an efficient foundation for solar‑plus‑storage systems in complex commercial environments.
Optimized Solar Integration & High Performance
Maximize Power Generation
-
8 MPPTs support highly flexible PV configurations with 200 % DC oversizing for larger PV arrays.
-
Up to 42 A max input current per MPPT improves compatibility with high‑current PV modules.
-
Excellent PV harvesting performance in varied irradiation and orientation scenarios.
Benefits:
-
Increased energy yield from commercial rooftop or ground‑mounted PV systems.
-
Flexible design supports multi‑string layouts for large PV fields.
Reliable Backup & Grid Support
Steady Power in Critical Conditions
-
UPS‑level function with < 4 ms switch time ensures uninterrupted power to critical loads during grid disturbances.
-
Supports 110 % unbalanced load and 150 % AC overloading for short durations, enhancing adaptability under uneven industrial loads.
-
Dual independent battery inputs allow up to 220 A total charge/discharge capability for flexible storage sizing.
Advantages:
-
Robust backup performance for essential loads.
-
Enhanced supply stability for commercial operations.
Intelligent Control & Flexible System Architecture
Smart Operation Modes
-
Supports advanced operating modes such as self‑consumption optimization, peak shaving, time‑of‑use, and grid support functions for C&I scenarios.
-
Compatible with generator control via digital interfaces for flexible hybrid systems.
-
AC/DC coupling capability offers simplified system design and improved round‑trip efficiency.
Benefits:
-
Reduced energy costs through intelligent dispatch and peak load management.
-
Flexible system integration for existing or new installations.
Durable Design & Industrial‑Grade Reliability
Built for Commercial Environments
-
IP66 ingress protection ensures reliable outdoor deployment and resistance to dust and moisture.
-
Smart temperature sensing and thermal monitoring prevent overheating and protect critical components.
-
Optional surge protection and smart DC circuit breaker increase system safety and fault isolation.
Advantages:
-
High reliability in demanding industrial or outdoor installations.
-
Multi‑layered protection for long‑term system operation.
Why Choose China Moneypro ET‑100 kW?
-
High Power & Scalability: Designed for commercial & industrial solar‑plus‑storage applications with up to 100 kW output class.
-
Advanced PV Integration: 8 MPPTs with 200 % oversizing capability for maximum PV generation.
-
Reliable Backup: < 4 ms UPS‑level switching and high overload capacity.
-
Flexible Operation: Supports multiple intelligent modes including peak shaving, self‑consumption, and grid support.
-
Robust Industrial Design: IP66 protection and smart thermal monitoring for outdoor commercial use.
Typical Applications
-
Commercial Rooftop Systems: High‑power PV + storage for retail, offices, and corporate facilities.
-
Industrial Energy Storage: Peak shaving, load management, and backup support in manufacturing and warehousing.
-
Grid Support & Ancillary Services: Provide grid‑friendly power injections and frequency support.
-
Hybrid Solar + Generator Systems: Flexible integration with generators for extended runtime.
FAQ – Common Questions
Q1: What power range does the ET Series cover?
The ET Series includes hybrid inverters in the 75–100 kW class, with the flagship unit at 100 kW output.
Q2: Can it handle large unbalanced loads?
Yes — it supports 110 % unbalanced three‑phase loads and 150 % short‑term AC overload, making it suitable for industrial equipment and uneven load profiles.
Q3: How many MPPTs are integrated?
The ET Series features 8 MPPTs, allowing flexible PV string layouts and high energy capture.
Q4: Does the inverter support backup power?
Yes — UPS‑level switching (< 4 ms) ensures critical loads remain powered during grid outages.
Q5: Is the ET Series suitable for outdoor installations?
The inverter has an IP66 protection rating, making it robust and reliable for outdoor commercial use.
Specifications
| Parameter | GW75K‑ET‑G10 | GW80K‑ET‑G10 | GW99.99K‑ET‑G10 | GW100K‑ET‑G10 |
|---|---|---|---|---|
| Battery Side | ||||
| Battery Type | Li‑Ion | Li‑Ion | Li‑Ion | Li‑Ion |
| Nominal Voltage (V) | 600 | 600 | 600 | 600 |
| Voltage Range (V) | 300 ~ 800 | 300 ~ 800 | 300 ~ 800 | 300 ~ 800 |
| Start‑up Voltage (V) | 300 | 300 | 300 | 300 |
| Number of Battery Inputs | 2 | 2 | 2 | 2 |
| Max. Continuous Charging Current (A) | 85 × 2 | 100 × 2 | 110 × 2 | 110 × 2 |
| Max. Continuous Discharging Current (A) | 85 × 2 | 100 × 2 | 110 × 2 | 110 × 2 |
| Max. Charging Power (kW) | 75 | 88 | 99.99 | 110 |
| Max. Discharging Power (kW) | 75 | 88 | 99.99 | 110 |
| PV Side | ||||
| Max. Input Power (kW) | 150 | 160 | 200 | 200 |
| Max. Input Voltage (V)*¹ | 1000 | 1000 | 1000 | 1000 |
| MPPT Operating Voltage Range (V)*² | 160 ~ 950 | 160 ~ 950 | 160 ~ 950 | 160 ~ 950 |
| Start‑up Voltage (V) | 200 | 200 | 200 | 200 |
| Nominal Input Voltage (V) | 620 | 620 | 620 | 620 |
| Max. MPPT Current (A) | 42 × 8 | 42 × 8 | 42 × 8 | 42 × 8 |
| Max. MPPT Short Circuit Current (A) | 55 × 8 | 55 × 8 | 55 × 8 | 55 × 8 |
| Number of MPPTs | 8 | 8 | 8 | 8 |
| Number of Strings per MPPT | 2 | 2 | 2 | 2 |
| AC Side (On‑Grid) | ||||
| Nominal Power (kW) | 75 | 80 | 99.99 | 100 |
| Max. Power (kW) | 75 | 88 | 99.99 | 110 |
| Nominal Apparent Power to Grid (kVA) | 75 | 80 | 99.99 | 100 |
| Max. Apparent Power to Grid (kVA) | 75 | 88 | 99.99 | 110 |
| Nominal Voltage (V) | 220/380, 230/400, 240/415, 3L/N/PE | 220/380, 230/400, 240/415, 3L/N/PE | 220/380, 230/400, 240/415, 3L/N/PE | 220/380, 230/400, 240/415, 3L/N/PE |
| Voltage Range (V) | According to local standard | According to local standard | According to local standard | According to local standard |
| Nominal Frequency (Hz) | 50/60 | 50/60 | 50/60 | 50/60 |
| Frequency Range (Hz) | 45 ~ 55 / 55 ~ 65 | 45 ~ 55 / 55 ~ 65 | 45 ~ 55 / 55 ~ 65 | 45 ~ 55 / 55 ~ 65 |
| Nominal Current (A) | 114.0 @380Vac; 108.3 @400Vac; 104.4 @415Vac | 121.6 @380Vac; 115.5 @400Vac; 111.3 @415Vac | 152.0 @380Vac; 144.4 @400Vac; 139.2 @415Vac | 152.0 @380Vac; 144.4 @400Vac; 139.2 @415Vac |
| Max. Current (A) | 114.0 @380Vac; 108.3 @400Vac; 104.4 @415Vac | 133.8 @380Vac; 127.1 @400Vac; 122.5 @415Vac | 152.0 @380Vac; 144.4 @400Vac; 139.2 @415Vac | 167.2 @380Vac; 158.8 @400Vac; 153.1 @415Vac |
| Power Factor | 0.8 leading ~ 0.8 lagging | 0.8 leading ~ 0.8 lagging | 0.8 leading ~ 0.8 lagging | 0.8 leading ~ 0.8 lagging |
| THDi | < 3% | < 3% | < 3% | < 3% |
| Backup Side | ||||
| Nominal Output Apparent Power (kVA) | 75 | 80 | 99.99 | 100 |
| Max. Output Apparent Power (kVA) | 75 | 88 | 99.99 | 110 |
| Peak Output Power without Grid | 120% @ 60s; 150% @ 10s | 110% @ continuous; 120% @ 60s; 150% @ 10s | 120% @ 60s; 150% @ 10s | 110% @ continuous; 120% @ 60s; 150% @ 10s |
| Nominal Output Voltage (V) | 220/380, 230/400, 240/415, 3L/N/PE | 220/380, 230/400, 240/415, 3L/N/PE | 220/380, 230/400, 240/415, 3L/N/PE | 220/380, 230/400, 240/415, 3L/N/PE |
| Nominal Output Frequency (Hz) | 50/60 | 50/60 | 50/60 | 50/60 |
| Max. Output Current (A) | 114.0 @380Vac; 108.3 @400Vac; 104.4 @415Vac | 133.8 @380Vac; 127.1 @400Vac; 122.5 @415Vac | 152.0 @380Vac; 144.4 @400Vac; 139.2 @415Vac | 167.2 @380Vac; 158.8 @400Vac; 153.1 @415Vac |
| THDv (@ Linear Load) | < 3% | < 3% | < 3% | < 3% |
| On/Off‑grid Switching Time | < 4 ms | < 4 ms | < 4 ms | < 4 ms |
| Efficiency | ||||
| Max. Efficiency | 98.1% | 98.1% | 98.1% | 98.1% |
| European Efficiency | 97.7% | 97.7% | 97.7% | 97.7% |
| Max. Battery‑to‑AC Efficiency | 98.2% | 98.2% | 98.2% | 98.2% |
| MPPT Efficiency | 99.9% | 99.9% | 99.9% | 99.9% |
| Protection | ||||
| PV String Current Monitoring | Integrated | Integrated | Integrated | Integrated |
| PV Insulation Resistance Detection | Integrated | Integrated | Integrated | Integrated |
| Residual Current Monitoring | Integrated | Integrated | Integrated | Integrated |
| PV Reverse Polarity Protection | Integrated | Integrated | Integrated | Integrated |
| Battery Reverse Polarity Protection | Integrated | Integrated | Integrated | Integrated |
| Anti‑islanding Protection | Integrated | Integrated | Integrated | Integrated |
| AC Overcurrent Protection | Integrated | Integrated | Integrated | Integrated |
| AC Short Circuit Protection | Integrated | Integrated | Integrated | Integrated |
| AC Overvoltage Protection | Integrated | Integrated | Integrated | Integrated |
| DC Switch | Integrated | Integrated | Integrated | Integrated |
| DC Surge Protection | Type II (Type I + II Optional) | Type II (Type I + II Optional) | Type II (Type I + II Optional) | Type II (Type I + II Optional) |
| AC Surge Protection | Type II | Type II | Type II | Type II |
| AFCI | Optional | Optional | Optional | Optional |
| Rapid Shutdown | Optional | Optional | Optional | Optional |
| Remote Shutdown | Optional | Optional | Optional | Optional |
| General Data | ||||
| Operating Temperature Range (°C) | -35 ~ +60 | -35 ~ +60 | -35 ~ +60 | -35 ~ +60 |
| Relative Humidity | 0 ~ 100% | 0 ~ 100% | 0 ~ 100% | 0 ~ 100% |
| Max. Operating Altitude (m) | 4000 | 4000 | 4000 | 4000 |
| Cooling Method | Smart Fan Cooling | Smart Fan Cooling | Smart Fan Cooling | Smart Fan Cooling |
| User Interface | LED, LCD (Optional), WLAN + APP | LED, LCD (Optional), WLAN + APP | LED, LCD (Optional), WLAN + APP | LED, LCD (Optional), WLAN + APP |
| Communication with BMS | CAN | CAN | CAN | CAN |
| Communication | RS485, Wi‑Fi + LAN + Bluetooth, 4G + Bluetooth (Optional) | RS485, Wi‑Fi + LAN + Bluetooth, 4G + Bluetooth (Optional) | RS485, Wi‑Fi + LAN + Bluetooth, 4G + Bluetooth (Optional) | RS485, Wi‑Fi + LAN + Bluetooth, 4G + Bluetooth (Optional) |
| Communication Protocols | Modbus‑RTU, Modbus‑TCP | Modbus‑RTU, Modbus‑TCP | Modbus‑RTU, Modbus‑TCP | Modbus‑RTU, Modbus‑TCP |
| Weight (kg) | 97 | 97 | 97 | 97 |
| Dimension (W × H × D mm) | 995 × 758 × 358 | 995 × 758 × 358 | 995 × 758 × 358 | 995 × 758 × 358 |
| Noise Emission (dB) | < 60 | < 60 | < 60 | < 60 |
| Power Self‑consumption at Night (W) | < 15 | < 15 | < 15 | < 15 |
| Ingress Protection Rating | IP66 | IP66 | IP66 | IP66 |
| Anti‑corrosion Class | C4 | C4 | C4 | C4 |
| Mounting Method | Wall Mounted | Wall Mounted | Wall Mounted | Wall Mounted |