MP-SG3300UD-530
Utility-scale solar projects face high costs, complex grid integration, and extreme temperature conditions. The China Moneypro SG3300UD is engineered to address these issues with a robust 1500Vdc PV inverter that combines high efficiency, intelligent operation, and cost-effective deployment.
Overcoming Utility-Scale PV Challenges
Utility-scale solar projects face high costs, complex grid integration, and extreme temperature conditions. The China Moneypro SG3300UD is engineered to address these issues with a robust 1500Vdc PV inverter that combines high efficiency, intelligent operation, and cost-effective deployment.
Maximum Energy Yield
Efficient Power Conversion
-
Advanced three-level technology achieves up to 99% inverter efficiency.
-
Enhanced cooling system enables full power output at 45??C.
User Benefits:
-
Higher energy output from each PV module
-
Stable performance in hot climates
-
Improved ROI for utility-scale PV installations
Smart Operations & Maintenance
Simplified Monitoring and Maintenance
-
Integrated zone monitoring allows real-time online analysis and fault detection.
-
Modular design ensures easy maintenance and quick component replacement.
Advantages:
-
Minimized downtime
-
Lower operational costs
-
Faster fault resolution
Cost-Effective Deployment
Lower System Investment
-
Outdoor-ready design reduces transportation and installation complexity.
-
DC 1500V system lowers overall system cost.
-
Optional Q-at-night function improves energy efficiency.
Grid Support & Compliance
Reliable Grid Integration
-
Complies with IEC 61727 and IEC 62116 standards.
-
Supports Low/High Voltage Ride Through (L/HVRT).
-
Active & reactive power control with managed power ramp rates.
Benefits:
-
Stable performance during grid fluctuations
-
Compliance with global grid requirements
-
Supports advanced utility grid management
Key Specifications
-
Max PV Input Voltage: 1500 V
-
AC Output Power: 3300 kVA
-
Nominal AC Voltage: 630 V
-
Maximum Efficiency: 99%
Typical Applications
-
Large-Scale Utility PV Plants: High-efficiency inverter reduces total system costs.
-
Smart Grid Integration: Provides reactive power support and voltage stabilization.
-
Harsh Environmental Conditions: Thermal management maintains reliable operation at elevated temperatures.
FAQ ?C Common Questions
Q1: How does the SG3300UD improve PV system yield?
Through advanced three-level technology and full power operation at 45??C, ensuring maximum energy harvest.
Q2: How is maintenance simplified?
Its modular design and integrated zone monitoring allow rapid maintenance and fault detection.
Q3: Can it handle voltage fluctuations on the grid?
Yes. The inverter supports L/HVRT and active/reactive power control for grid stability.
Q4: Is it suitable for outdoor installations?
Absolutely. The robust outdoor-ready design reduces installation complexity and costs.
Q5: Does it save energy at night?
Optional Q-at-night function reduces energy losses during low-sun periods.
The SG3300UD ensures high yield, smart O&M, cost efficiency, and reliable grid support, making it ideal for 1500Vdc utility-scale solar projects.
Specifications
| Type designationSG3300UDSG4400UD | ||
| Input (DC) | ||
| Max. PV input voltage | 1500 V | |
| Min. PV input voltage / Startup input voltage | 895 V / 905 V | |
| MPP voltage range | 895 V – 1500 V | |
| No. of independent MPP inputs | 34 | |
| No. of DC inputs | 15 ( optional: 21 )20 ( optional: 28 ) | |
| Max. PV input current | 3 * 1435 A4 * 1435 A | |
| Max. DC short-circuit current | 3 * 3528 A4 * 3528 A | |
| PV array confguration | Negative grounding or foating | |
| Output (AC) | ||
| AC output power | 3300 kVA @ 45 ℃
3399 kVA @ 40 ℃ 3795 kVA @ 22.5 ℃ |
4400 kVA @ 45 ℃
4532 kVA @ 40 ℃ 5060 kVA @ 22.5 ℃ |
| Max. AC output current | 3 * 1160 A4 * 1160 A | |
| Nominal AC voltage | 630 V | |
| AC voltage range | 536 V – 693 V | |
| Nominal grid frequency / Grid frequency range | 50 Hz / 45 Hz – 55 Hz, 60 Hz / 55 Hz – 65 Hz | |
| Harmonic (THD) | < 1.5 % ( at nominal power ) | |
| Power factor at nominal power / Adjustable power factor | > 0.99 / 0.8 leading – 0.8 lagging | |
| Feed-in phases / AC connection | 3 / 3 | |
| Effciency | ||
| Max. effciency / European effciency | 99.0 % / 98.8 % | |
| Protection & Function | ||
| DC input protection | Load break switch + fuse | |
| AC output protection | Circuit breaker | |
| Overvoltage protection | DC Type II / AC Type II | |
| Grid monitoring / Ground fault monitoring | Yes / Yes | |
| Insulation monitoring | Yes | |
| Surge protection | Yes | |
| Q at night function | Optional | |
| General data | ||
| Dimensions (W*H*D) | 2340 mm * 2300 mm * 1550 mm2900 mm * 2300 mm * 1550 mm | |
| Weight | 2.5 T3.3 T | |
| Topology | Transformerless | |
| Degree of protection | IP65 | |
| Night power consumption | < 200 W | |
| Operating ambient temperature range * | -35 ℃ – 60 ℃ | |
| Allowable relative humidity range | 0 % – 100 % | |
| Cooling method | Temperature controlled forced air cooling | |
| Max. operating altitude | 4000 m ( > 3000 m derating ) | |
| Display | LED Indicators, Ethernet+WebHMI | |
| Communication | Standard: RS485, Ethernet | |
| Compliance | CE, IEC 62109, IEC 61727, IEC 62116, IEC 60068, IEC 61683, VDE-AR-N
4110:2018, VDE-AR-N 4120:2018, EN 50549-2, UNE 206007-1:2013, NTS 631, UTE C15-712-1:2013 |
|