MP-SG1100UD-7093
The China Moneypro SG1100UD-20 is designed for high-efficiency, reliable, and cost-effective PV power generation. Optimized for 1500Vdc systems, it delivers superior performance even in high-temperature environments.
Maximize Utility-Scale Solar Output
The China Moneypro SG1100UD-20 is designed for high-efficiency, reliable, and cost-effective PV power generation. Optimized for 1500Vdc systems, it delivers superior performance even in high-temperature environments.
High Yield
Advanced Power Conversion
-
Three-level technology achieves up to 99% inverter efficiency.
-
Effective cooling allows full power operation at 52??C.
Benefits:
-
Maximizes energy harvested from PV modules
-
Stable performance in hot climates
-
Improved ROI for utility-scale projects
Intelligent Operations & Maintenance
Simplified Fault Management
-
Integrated zone monitoring enables real-time online analysis and troubleshooting.
-
Modular design ensures fast and easy maintenance.
Advantages:
-
Minimal downtime
-
Reduced O&M costs
-
Quick fault resolution
Cost-Effective Deployment
Lower System Investment
-
Outdoor-ready design reduces transportation and installation complexity.
-
DC 1500V system lowers overall system cost.
-
Optional Q-at-night function enhances energy efficiency.
Grid Support & Compliance
Stable Grid Integration
-
Complies with IEC 61727 and IEC 62116 standards.
-
Supports Low/High Voltage Ride Through (L/HVRT).
-
Active & reactive power control with controlled ramp rates.
Benefits:
-
Maintains stable grid performance
-
Meets international compliance requirements
-
Supports advanced utility grid management
Why Choose China Moneypro SG1100UD-20?
-
Proven Reliability: 1500Vdc design with robust outdoor operation and modular maintenance.
-
High Efficiency: Advanced three-level technology maximizes energy output.
-
Global Compliance: Meets international grid codes for safe and stable operation.
-
Lower Costs: Outdoor design reduces transportation and installation expenses.
-
Easy Maintenance: Modular, split design allows quick repairs and system monitoring.
Key Specifications
-
Max PV Input Voltage: 1500 V
-
AC Output Power: 1100 kVA
-
Nominal AC Voltage: 660 V
-
Maximum Efficiency: 99%
Typical Applications
-
Utility-Scale PV Plants: High-efficiency inverter lowers total system costs.
-
Grid Integration: Supports reactive power dispatch and voltage regulation.
-
Harsh Environments: Thermal management ensures reliable operation at high temperatures.
FAQ ?C Common Questions
Q1: How does SG1100UD-20 maximize yield?
Through three-level power conversion and full power operation at 52??C, ensuring maximum energy capture.
Q2: How is maintenance simplified?
Its modular design and zone monitoring allow rapid maintenance and fault detection.
Q3: Can it handle voltage fluctuations?
Yes, it supports L/HVRT and active/reactive power control for grid stability.
Q4: Is it suitable for outdoor deployment?
Absolutely. Outdoor-ready design minimizes installation complexity and costs.
Q5: Does it save energy during low-sun periods?
Yes. Optional Q-at-night function reduces energy losses during nighttime.
Specifications
| Input (DC)
Max. PV input voltage |
1500 V |
| Min. PV input voltage / Startup input voltage | 938 V / 950 V |
| MPP voltage range | 938 V – 1500 V |
| No. of independent MPP inputs | 1 |
| No. of DC inputs | 5 ( optional: 7 ) |
| Max. PV input current | 1435 A |
| Max. DC short-circuit current | 3528 A |
| PV array confguration | Negative grounding or foating |
| Output (AC) | |
| AC output power | 1100 kVA @ 52 ℃, 1320 kVA @ 23 ℃ |
| Max. AC output current | 1155 A |
| Nominal AC voltage | 660 V |
| AC voltage range | 561 V – 726 V |
| Nominal grid frequency / Grid frequency range | 50 Hz / 45 Hz – 55 Hz, 60 Hz / 55 Hz – 65 Hz |
| Harmonic (THD) | < 1.5 % ( at nominal power ) |
| Power factor at nominal power / Adjustable power factor | > 0.99 / 0.8 leading – 0.8 lagging |
| Feed-in phases / AC connection | 3 / 3 |
| Effciency | |
| Max. effciency / European effciency | 99.0 % / 98.7 % |
| Protection & Function | |
| DC input protection | Load break switch + fuse |
| AC output protection | Circuit breaker |
| Surge protection | DC Type II / AC Type II |
| Grid monitoring / Ground fault monitoring | Yes / Yes |
| Insulation monitoring | Yes |
| Surge protection | Yes |
| Q at night function | Optional |
| General data | |
| Dimensions (W*H*D) | 700 mm * 2290 mm * 1525 mm |
| Weight | 800 kg |
| Topology | Transformerless |
| Degree of protection | IP65 |
| Night power consumption | < 200 W |
| Operating ambient temperature range * | -35 ℃ – 60 ℃ |
| Allowable relative humidity range | 0 % – 100 % |
| Cooling method | Temperature controlled forced air cooling |
| Max. operating altitude | 4000 m ( > 2000 m derating ) |
| Display | LED Indicators, Ethernet+WebHMI |
| Communication | Standard: RS485, Ethernet |
| Compliance | CE, IEC 62109, IEC 61727, IEC 62116, IEC 60068, IEC 61683 |