MP-ESA Series 5?C30kW/5?C108kWh Three Phase All-in-One ESS-7388
The China Moneypro ESA Series is a three-phase all-in-one energy storage system designed for residential and small commercial applications. It integrates the hybrid inverter, battery modules, and intelligent energy management into a single, pre-wired modular unit, significantly reducing installation complexity and supporting fast commissioning. With multiple battery module capacities and scalable expansion up to 108 kWh, the ESA Series adapts to evolving energy needs while enabling smart solar self-consumption and whole-home backup.
Smart, Integrated & Scalable Storage Solution
The China Moneypro ESA Series is a three-phase all-in-one energy storage system designed for residential and small commercial applications. It integrates the hybrid inverter, battery modules, and intelligent energy management into a single, pre-wired modular unit, significantly reducing installation complexity and supporting fast commissioning. With multiple battery module capacities and scalable expansion up to 108 kWh, the ESA Series adapts to evolving energy needs while enabling smart solar self-consumption and whole-home backup.
Compact & Flexible Design
Tailored to Growing Energy Demands
-
Pre-wired modular architecture combines inverter and battery into one integrated system.
-
Supports up to 12 battery modules with four choices — 5 kWh, 6 kWh*, 8 kWh, and 9 kWh* — for flexible total storage up to 108 kWh.
-
Flexible battery mixing allows combining different capacities or old & new modules for investment protection and future upgrades.
Benefits:
-
Expand capacity without replacing existing batteries.
-
Tailor energy storage size to household or small commercial demands.
-
Simplify system scaling with plug-and-play modularity.
*6 kWh & 9 kWh modules coming soon.
High Performance & Quiet Operation
Optimize Solar Generation & Delivery
-
1C charge/discharge supports fast, daily cycling of stored energy.
-
Up to 200 % DC oversizing on PV input and AC backup overload provide better solar utilization and larger generation capture.
-
Intelligent AI-driven EMS helps optimize energy dispatch and tariff savings.
-
Quiet operation (< 30 dB) makes installation suitable even in noise-sensitive environments.
Advantages:
-
Maximize solar self-consumption even with heavy load.
-
Maintain a quieter home setting with low noise levels.
-
Faster return on investment via efficient energy cycling.
Reliable Backup & Fast Switching
Power Continuity for Critical Loads
-
Seamless UPS-level switching < 4 ms ensures uninterrupted power delivery for essential appliances.
-
Dual-port design supports whole-home backup capability.
-
Up to six systems in parallel support higher total power for large homes or small commercial sites.
Benefits:
-
Minimal disruption during grid outages.
-
Extend backup capability with parallel systems.
-
Protect sensitive electronics and systems from blackouts.
Safe, Durable & Harsh-Climate Ready
Built for Everyday Use
-
Advanced six-layer safety protection guards from cell to system-level hazards.
-
AI-driven AFCI 3.0 reduces arc-fault risk for enhanced fire safety.
-
Heating mode enables stable performance even in cold climates (as low as –20 °C).
-
IP66 protection rating supports both indoor and sheltered outdoor installation.
Advantages:
-
More robust safety and protection than basic storage systems.
-
Reliable performance across a wide range of climates.
-
Peace of mind for long-term operations.
Why Choose China Moneypro ESA Series?
-
All-in-One Design: Combines inverter, battery, and EMS for simplicity and speed of installation.
-
Scalable Capacity: From 5 kWh up to 108 kWh storage via modular expansion.
-
Efficient Cycling: 1C rapid charge/discharge improves daily performance.
-
Reliable Backup: < 4 ms UPS switching for uninterrupted power delivery.
-
Smart EMS: AI-driven energy management optimizes solar utilization and costs.
-
Durable & Quiet: IP66 protection and < 30 dB operation ensure a comfortable, rugged system.
Key Specifications (Typical Models)
| Model | Rated Power | Battery Voltage Range | Max. Charge / Discharge Current | Backup Power |
|---|---|---|---|---|
| 5 kW variant | 5 kVA | 700–950 V | 6.7 / 7.4 A | 5 kVA |
| 6 kW variant | 6 kVA | 700–950 V | 8.1 / 8.9 A | 6 kVA |
| 8 kW variant | 8 kVA | 700–950 V | 10.7 / 11.8 A | 8 kVA |
| 10 kW variant | 10 kVA | 700–950 V | 13.4 / 14.7 A | 10 kVA |
| 12 kW variant | 12 kVA | 700–950 V | 16.1 / 17.7 A | 12 kVA |
| 15 kW variant | 15 kVA | 700–950 V | 20.1 / 22.1 A | 15 kVA |
| 20 kW variant | 20 kVA | 700–950 V | 26.7 / 29.4 A | 20 kVA |
| 25 kW variant | 25 kVA | 700–950 V | 33.3 / 36.7 A | 25 kVA |
| 30 kW variant | 30 kVA | 700–950 V | 40.0 / 44.1 A | 30 kVA |
Typical figures for ESA 5–30 kW HV system; specific values depend on model and battery configuration.
Typical Applications
-
Residential Solar + Storage: Store excess PV generation for evening/peak use.
-
Whole-Home Backup: Provide reliable backup during outages.
-
Small Commercial Sites: Scalable power for offices, shops, and light industry.
-
Peak Shaving & Energy Cost Optimization: Shift solar energy use to high-tariff periods.
FAQ – Common Questions
Q1: What power range does the ESA Series cover?
The system is available in 5–30 kW three-phase variants.
Q2: How scalable is the ESA Series’ storage capacity?
It supports up to 12 battery modules (5, 6, 8, or 9 kWh) for a total potential of ~108 kWh.
Q3: Can different battery capacities mix in one system?
Yes — the ESA Series supports flexible battery mixing to use old and new modules together.
Q4: How quickly does it switch to backup power?
The system provides UPS-level switching in < 4 ms, maintaining continuous power for critical loads.
Q5: What safety features are included?
Advanced six-layer protection and AI-driven AFCI 3.0 enhance safety at cell and system levels.
Specifications
|
Technical Data
|
GW3K-EHA-G20
|
GW3.6K-EHA-G20
|
GW5K-EHA-G20
|
GW6K-EHA-G20
|
GW8K-EHA-G20
|
GW9.999K-EHA-G20
|
GW10K-EHA-G20
|
|---|---|---|---|---|---|---|---|
|
Battery Side
|
|||||||
|
Battery Type
|
LiFePO4
|
LiFePO4
|
LiFePO4
|
LiFePO4
|
LiFePO4
|
LiFePO4
|
LiFePO4
|
|
Nominal Battery Voltage (V)
|
380
|
380
|
380
|
380
|
380
|
380
|
380
|
|
Battery Voltage Range (V)
|
350 ~ 550
|
350 ~ 550
|
350 ~ 550
|
350 ~ 550
|
350 ~ 550
|
350 ~ 550
|
350 ~ 550
|
|
Start-up Voltage (V)
|
380
|
380
|
380
|
380
|
380
|
380
|
380
|
|
Number of Battery Input
|
1
|
1
|
1
|
1
|
1
|
1
|
1
|
|
Max. Continuous Charging Current (A)
|
11.9
|
14.3
|
19.8
|
23.7
|
31.6
|
35.6
|
35.6
|
|
Max. Continuous Discharging Current (A)
|
8.7
|
10.5
|
14.5
|
17.4
|
23.2
|
29.0
|
29.0
|
|
Max. Charging Power (kW)
|
3.3
|
3.96
|
5.5
|
6.6
|
8.8
|
11.0
|
11.0
|
|
Max. Discharging Power (kW)
|
3.3
|
3.96
|
5.5
|
6.6
|
8.8
|
11.0
|
11.0
|
|
PV Side
|
|||||||
|
Max. Input Power (kW)
|
6.0
|
7.2
|
10.0
|
12.0
|
16.0
|
20.0
|
20.0
|
|
Max. Input Voltage (V)
|
600
|
600
|
600
|
600
|
600
|
600
|
600
|
|
MPPT Operating Voltage Range (V)
|
40 ~ 560
|
40 ~ 560
|
40 ~ 560
|
40 ~ 560
|
40 ~ 560
|
40 ~ 560
|
40 ~ 560
|
|
Start-up Voltage (V)
|
50
|
50
|
50
|
50
|
50
|
50
|
50
|
|
Nominal Input Voltage (V)
|
400
|
400
|
400
|
400
|
400
|
400
|
400
|
|
Max. MPPT Current (A)
|
20
|
20
|
20
|
20
|
20
|
20
|
20
|
|
Max. MPPT Short Circuit Current (A)
|
26
|
26
|
26
|
26
|
26
|
26
|
26
|
|
Number of MPPTs
|
2
|
2
|
2
|
2
|
4
|
4
|
4
|
|
Number of Strings per MPPT
|
1/1
|
1/1
|
1/1
|
1/1
|
1/1/1/1
|
1/1/1/1
|
1/1/1/1
|
|
AC Side (On-grid)
|
|||||||
|
Nominal Power (kW)
|
3.0
|
3.6
|
5.0
|
6.0
|
8.0
|
9.999
|
10.0
|
|
Nominal Apparent Power to Grid (kVA)
|
3.0
|
3.6
|
5.0
|
6.0
|
8.0
|
9.999
|
10.0
|
|
Max. Apparent Power to Grid (kVA)
|
6.0
|
7.2
|
10.0
|
12.0
|
14.5
|
14.5
|
14.5
|
|
Max. Apparent Power from Grid (kVA)
|
6.0
|
7.2
|
10.0
|
12.0
|
14.5
|
14.5
|
14.5
|
|
Nominal Voltage (V)
|
220 / 230 / 240, L / N / PE
|
220 / 230 / 240, L / N / PE
|
220 / 230 / 240, L / N / PE
|
220 / 230 / 240, L / N / PE
|
220 / 230 / 240, L / N / PE
|
220 / 230 / 240, L / N / PE
|
220 / 230 / 240, L / N / PE
|
|
Voltage Range (V)
|
170 ~ 280
|
170 ~ 280
|
170 ~ 280
|
170 ~ 280
|
170 ~ 280
|
170 ~ 280
|
170 ~ 280
|
|
Nominal Frequency (Hz)
|
50 / 60
|
50 / 60
|
50 / 60
|
50 / 60
|
50 / 60
|
50 / 60
|
50 / 60
|
|
Frequency Range (Hz)
|
45 ~ 55 / 55 ~ 65
|
45 ~ 55 / 55 ~ 65
|
45 ~ 55 / 55 ~ 65
|
45 ~ 55 / 55 ~ 65
|
45 ~ 55 / 55 ~ 65
|
45 ~ 55 / 55 ~ 65
|
45 ~ 55 / 55 ~ 65
|
|
Max. Current to Grid (A)
|
13.7 @ 220V / 13.7 @ 240V
|
16.4 @ 220V / 15.4 @ 230V / 15.0 @ 240V
|
22.8 @ 220V / 21.7 @ 230V / 20.8 @ 240V
|
27.3 @ 220V / 26.1 @ 230V / 25.0 @ 240V
|
36.4 @ 220V / 34.8 @ 230V / 33.4 @ 240V
|
43.5 @ 220V / 43.5 @ 230V / 41.7 @ 240V
|
43.5 @ 220V / 43.5 @ 230V / 41.7 @ 240V
|
|
Max. Current From Grid (A)
|
27.3 @ 220V / 26.1 @ 230V / 25.0 @ 240V
|
32.8 @ 220V / 31.3 @ 230V / 30.0 @ 240V
|
45.5 @ 220V / 43.5 @ 230V / 41.7 @ 240V
|
50.0 @ 220V / 50.0 @ 230V / 50.0 @ 240V
|
63.0 @ 220V / 63.0 @ 230V / 60.5 @ 240V
|
63.0 @ 220V / 63.0 @ 230V / 60.5 @ 240V
|
63.0 @ 220V / 63.0 @ 230V / 60.5 @ 240V
|
|
Power Factor
|
~1 (Adjustable from 0.8 leading to 0.8 lagging)
|
~1 (Adjustable from 0.8 leading to 0.8 lagging)
|
~1 (Adjustable from 0.8 leading to 0.8 lagging)
|
~1 (Adjustable from 0.8 leading to 0.8 lagging)
|
~1 (Adjustable from 0.8 leading to 0.8 lagging)
|
~1 (Adjustable from 0.8 leading to 0.8 lagging)
|
~1 (Adjustable from 0.8 leading to 0.8 lagging)
|
|
THDi
|
<3%
|
<3%
|
<3%
|
<3%
|
<3%
|
<3%
|
<3%
|
|
Back-up Side
|
|||||||
|
Nominal Output Apparent Power (kVA)
|
3.0
|
3.6
|
5.0
|
6.0
|
8.0
|
10.0
|
10.0
|
|
Max. Output Apparent Power (kVA)
|
3.0 (6.0, 10s)
|
3.6 (7.2, 10s)
|
5.0 (10.0, 10s)
|
6.0 (12.0, 10s)
|
8.0 (16.0, 10s)
|
10.0 (20.0, 10s)
|
10.0 (20.0, 10s)
|
|
Max. Output Apparent Power (Bypass) (kVA)
|
6.0
|
7.2
|
10.0
|
12.0
|
14.5
|
14.5
|
14.5
|
|
Max. Output Current (A)
|
13.7 @ 220V / 13.7 @ 240V
|
16.4 @ 220V / 15.4 @ 230V / 15.0 @ 240V
|
22.8 @ 220V / 21.7 @ 230V / 20.8 @ 240V
|
27.3 @ 220V / 26.1 @ 230V / 25.0 @ 240V
|
36.4 @ 220V / 34.8 @ 230V / 33.4 @ 240V
|
43.5 @ 220V / 43.5 @ 230V / 41.7 @ 240V
|
43.5 @ 220V / 43.5 @ 230V / 41.7 @ 240V
|
|
Max. Output Current (Bypass) (A)
|
27.3 @ 220V / 26.1 @ 230V / 25.0 @ 240V
|
32.8 @ 220V / 31.3 @ 230V / 30.0 @ 240V
|
45.5 @ 220V / 43.5 @ 230V / 41.7 @ 240V
|
50.0 @ 220V / 50.0 @ 230V / 50.0 @ 240V
|
63.0 @ 220V / 63.0 @ 230V / 60.5 @ 240V
|
63.0 @ 220V / 63.0 @ 230V / 60.5 @ 240V
|
63.0 @ 220V / 63.0 @ 230V / 60.5 @ 240V
|
|
Nominal Output Voltage (V)
|
220 / 230 / 240, L / N / PE
|
220 / 230 / 240, L / N / PE
|
220 / 230 / 240, L / N / PE
|
220 / 230 / 240, L / N / PE
|
220 / 230 / 240, L / N / PE
|
220 / 230 / 240, L / N / PE
|
220 / 230 / 240, L / N / PE
|
|
Nominal Output Frequency (Hz)
|
50 / 60
|
50 / 60
|
50 / 60
|
50 / 60
|
50 / 60
|
50 / 60
|
50 / 60
|
|
THDv (@Linear Load)
|
<3%
|
<3%
|
<3%
|
<3%
|
<3%
|
<3%
|
<3%
|
|
Efficiency
|
|||||||
|
Max. Efficiency
|
97.6%
|
97.6%
|
97.6%
|
97.6%
|
97.5%
|
97.5%
|
97.5%
|
|
European Efficiency
|
96.5%
|
96.5%
|
96.8%
|
97.0%
|
96.8%
|
96.8%
|
96.8%
|
|
Max. Battery to AC Efficiency
|
98.0%
|
98.0%
|
98.0%
|
98.0%
|
97.8%
|
97.8%
|
97.8%
|
|
Protection
|
|||||||
|
PV String Current Monitoring
|
Integrated
|
Integrated
|
Integrated
|
Integrated
|
Integrated
|
Integrated
|
Integrated
|
|
PV Insulation Resistance Detection
|
Integrated
|
Integrated
|
Integrated
|
Integrated
|
Integrated
|
Integrated
|
Integrated
|
|
Residual Current Monitoring
|
Integrated
|
Integrated
|
Integrated
|
Integrated
|
Integrated
|
Integrated
|
Integrated
|
|
PV Reverse Polarity Protection
|
Integrated
|
Integrated
|
Integrated
|
Integrated
|
Integrated
|
Integrated
|
Integrated
|
|
Battery Reverse Polarity Protection
|
Integrated
|
Integrated
|
Integrated
|
Integrated
|
Integrated
|
Integrated
|
Integrated
|
|
Anti-islanding Protection
|
Integrated
|
Integrated
|
Integrated
|
Integrated
|
Integrated
|
Integrated
|
Integrated
|
|
AC Overcurrent Protection
|
Integrated
|
Integrated
|
Integrated
|
Integrated
|
Integrated
|
Integrated
|
Integrated
|
|
AC Short Circuit Protection
|
Integrated
|
Integrated
|
Integrated
|
Integrated
|
Integrated
|
Integrated
|
Integrated
|
|
AC Overvoltage Protection
|
Integrated
|
Integrated
|
Integrated
|
Integrated
|
Integrated
|
Integrated
|
Integrated
|
|
DC Surge Protection
|
Type II
|
Type II
|
Type II
|
Type II
|
Type II
|
Type II
|
Type II
|
|
AC Surge Protection
|
Type II
|
Type II
|
Type II
|
Type II
|
Type II
|
Type II
|
Type II
|