MP-ES LD Series 5?C10 kW Split & Two Phase Hybrid Inverter-5668

The China Moneypro ES LD Series is a 5~10kW split & two-phase hybrid inverter designed for residential and small commercial energy storage systems. It offers flexible compatibility with both on-grid and off-grid configurations and supports 48 V low-voltage lithium or lead-acid batteries for efficient storage and use of solar energy. With a plug-and-play design, compact structure, and intuitive setup, the ES LD makes installation, operation, and maintenance easier. Its seamless switching in under 4 ms ensures your essential loads remain powered without interruption, while intelligent safety features and adaptable output options enhance overall system performance and reliability.

Share your love

Reliable Hybrid Energy for Homes & Small Businesses

The China Moneypro ES LD Series is a 5~10kW split & two-phase hybrid inverter designed for residential and small commercial energy storage systems. It offers flexible compatibility with both on-grid and off-grid configurations and supports 48 V low-voltage lithium or lead-acid batteries for efficient storage and use of solar energy. With a plug-and-play design, compact structure, and intuitive setup, the ES LD makes installation, operation, and maintenance easier. Its seamless switching in under 4 ms ensures your essential loads remain powered without interruption, while intelligent safety features and adaptable output options enhance overall system performance and reliability.


Seamless Backup Power

Fast and Dependable Transition

  • The ES LD Series delivers seamless switching in less than 4 ms, ensuring critical loads stay powered during grid disturbances.

  • Full compatibility with generators, including support for battery charging via generator, enhances reliability during extended outages.

Advantages:

  • Reliable protection for essential appliances.

  • Strong support for emergency power needs.

  • Eliminates disruption during grid failures.


High Performance & Flexible System Use

Adaptable for Multiple Scenarios

  • 20 A per string input supports high-performance solar integration.

  • Up to 200% DC oversizing and 200% AC overload for greater energy flexibility.

  • Supports on-grid and off-grid parallel operation, catering to diverse system configurations.

  • Offers both two-phase and split-phase output options to meet regional electrical requirements.

Benefits:

  • Efficient solar energy conversion and utilization.

  • Flexible arrangement for diverse household loads.

  • Compatible with complex rooftop and power system architectures.


Compact & Thoughtful Design

Installation Made Easy

  • Plug-and-play architecture simplifies electrical connections and setup.

  • Compact form factor reduces installation space requirements, ideal for rooftop or indoor inverter placement.

Advantages:

  • Faster, safer, and more efficient onsite installation.

  • Less hassle for system commissioning and inspection.


Durable & Reliable Safety

Built to Last

  • IP66 ingress protection ensures resistance against dust and water, suitable for outdoor use.

  • Includes AI-driven AFCI 3.0 safety technology, improving arc fault detection and minimizing fire risk.

Advantages:

  • Consistent performance in harsh environments.

  • Strong protection against electrical hazards.

  • Long-term system durability.


Why Choose China Moneypro ES LD Series?

  • Rapid Backup Switching: <4 ms seamless transition during grid outages.

  • High Performance: Supports 200% DC oversizing and 200% AC overload.

  • Flexible Output Options: Works with two-phase and split-phase designs.

  • Robust Safety: AI-driven AFCI 3.0 with IP66 protection.

  • Easy Integration: Plug-and-play design for simplified installation.


Key Specifications

  • Rated AC Output Power: 5~10 kW

  • Battery Voltage Range: 40~60 V

  • Max. Continuous Charging / Discharging Current:

    • 220 A (10 kW model)

    • 165 A (7.5 kW model)

    • 120 A (5 kW model)

  • Max. Input Current per MPPT:

    • 40/40 A (10 kW model)

    • 40/20 A (7.5 kW model)

    • 20/20 A (5 kW model)

  • Max. Apparent Power Output to Utility Grid: 5k–10k VA

  • Back-up Nominal Apparent Power: 5k–10k VA


Typical Applications

  • Residential Rooftops: Ideal for energy storage upgrades in homes.

  • Small Commercial Buildings: Supports flexible load profiles and higher energy demands.

  • On/Off-Grid Use Cases: Seamless transition and backup power during outages.

  • Generator Integration: Works with backup generators for extended power availability.


FAQ – Common Questions

Q1: How quickly does the ES LD Series switch to backup mode?
It provides seamless switching in under 4 ms, ensuring uninterrupted supply to essential loads.

Q2: Can it work both on-grid and off-grid?
Yes — it supports both on-grid and off-grid parallel operation for versatile system use.

Q3: What types of batteries are compatible?
It supports 48 V low-voltage lithium or lead-acid batteries for efficient energy storage.

Q4: Is it safe for outdoor installation?
Yes — IP66 ingress protection and advanced safety features like AFCI 3.0 make it suitable for outdoor use.

Q5: Are there different output voltage configurations?
Yes — the inverter supports multiple AC output voltages (120/208 V, 127/220 V, 120/240 V, 127/254 V) to meet diverse market needs.


Specifications

Technical Data GW5K-ES-LD-G10 GW7.5K-ES-LD-G10 GW10K-ES-LD-G10
Battery Side
Battery Type LFP / Lead-acid
Nominal Voltage (V) 48
Voltage Range (V) 40 ~ 60
Start-up Voltage (V) 44.2
Number of Battery Inputs 1
Max. Continuous Charging Current (A) 120                                                                           165                                                                           220
Max. Continuous Discharging Current (A) 120                                                                           165                                                                           220
Max. Charging Power (kW) 5.0                                                                            7.5                                                                           10.0
Max. Discharging Power (kW) 5.5                                                                            8.2                                                                           11.0
PV Side
Max. Input Power (kW) 10 15 20
Max. Input Voltage (V)*1 600
MPPT Operating Voltage Range (V)*2 50 ~ 550
Start-up Voltage (V) 60
Nominal Input Voltage (V) 360
Max. MPPT Current (A) 20 / 20 40 / 20 40 / 40
Max. MPPT Short Circuit Current (A) 26 / 26 52 / 26 52 / 52
Number of MPPTs 2
Number of Strings per MPPT 1 / 1 2 / 1 2 / 2
AC Side (Grid Port)
Rated Power (kW) 5.0 7.5 10.0
Max. Power (kW) 5.0 7.5 10.0
Rated Apparent Power from Grid (kVA) 5.0 7.5 10.0
Rated Apparent Power to Grid (kVA) 5.0 7.5 10.0
Max. Apparent Power to Grid (kVA) 5.0 7.5 10.0
Max. Apparent Power from Grid (kVA) 16.0 16.0 16.0
Nominal Voltage (V) 120 / 208, 2L / N / PE; 127 / 220, 2L / N / PE; 120 / 240, 2L / N / PE; 127 / 254, 2L / N / PE
Voltage Range (V) 170 ~ 290
Nominal Frequency (Hz) 50 / 60
Frequency Range (Hz) 45 ~ 55 / 55 ~ 65
Rated Current from Grid (A) 24.0@120/208V, 2L/N/PE; 22.7@127/220V, 2L/N/PE;
20.8@120/240V, 2L/N/PE; 19.7@127/254V, 2L/N/PE
36.1@120/208V, 2L/N/PE; 34.1@127/220V, 2L/N/PE
31.3@120/240V, 2L/N/PE; 29.5@127/254V, 2L/N/PE
48.1@120/208V, 2L/N/PE; 45.5@127/220V, 2L/N/PE
41.7@120/240V, 2L/N/PE; 39.4@127/254V, 2L/N/PE
Rated Current to Grid (A) 24.0@120/208V, 2L/N/PE; 22.7@127/220V, 2L/N/PE;
20.8@120/240V, 2L/N/PE; 19.7@127/254V, 2L/N/PE
36.1@120/208V, 2L/N/PE; 34.1@127/220V, 2L/N/PE
31.3@120/240V, 2L/N/PE; 29.5@127/254V, 2L/N/PE
48.1@120/208V, 2L/N/PE; 45.5@127/220V, 2L/N/PE
41.7@120/240V, 2L/N/PE; 39.4@127/254V, 2L/N/PE
Max. Current from Grid (A) 63
Max. Current to Grid (A) 24.0@120/208V, 2L/N/PE; 22.7@127/220V, 2L/N/PE;
20.8@120/240V, 2L/N/PE; 19.7@127/254V, 2L/N/PE
36.1@120/208V, 2L/N/PE; 34.1@127/220V, 2L/N/PE
31.3@120/240V, 2L/N/PE; 29.5@127/254V, 2L/N/PE
48.1@120/208V, 2L/N/PE; 45.5@127/220V, 2L/N/PE
41.7@120/240V, 2L/N/PE; 39.4@127/254V, 2L/N/PE
Power Factor 0.8 leading ~ 0.8 lagging
THDi <3%
AC Side (Back-up Port)
Rated Output Apparent Power (kVA) 5.0                                                                            7.5                                                                           10.0
Max. Output Apparent Power (kVA) Off-grid: 5.5 (10.0, 10s); On-grid: 16.0              Off-grid: 8.2 (15.0, 10s); On-grid: 16.0             Off-grid: 11.0 (20.0, 10s); On-grid: 16.0
Nominal Output Voltage (V) 120 / 208, 2L / N / PE; 127 / 220, 2L / N / PE; 120 / 240, 2L / N / PE; 127 / 254, 2L / N / PE
Nominal Output Frequency (Hz) 50 / 60
Max. Output Current (A)*3 Off-grid: 24.0; On-grid: 63.0                                Off-grid: 36.1; On-grid: 63.0                                Off-grid: 48.1; On-grid: 63.0
THDv (@Linear Load) <3%
On / Off-grid Switching Time (ms) ≤4
AC Side (Smart Port)
Rated Apparent Power (kVA) 5.0                                                                            7.5                                                                           10.0
Max. Apparent Power (kVA) 12.7
Nominal Voltage (V) 120 / 208, 2L / N / PE; 127 / 220, 2L / N / PE; 120 / 240, 2L / N / PE; 127 / 254, 2L / N / PE
Voltage Range (V) 170 ~ 290
Nominal Frequency (Hz) 50 / 60
Frequency Range (Hz) 45 ~ 55 / 55 ~ 65
Max. Current (A) 50
Efficiency
Max. Efficiency 97.6%
Max. Battery to AC Efficiency 95.5%
MPPT Efficiency 99.9%
Protection
PV String Current Monitoring Integrated
PV Insulation Resistance Detection Integrated
Residual Current Monitoring Integrated
PV Reverse Polarity Protection Integrated
Battery Reverse Polarity Protection Integrated
Anti-islanding Protection Integrated
AC Overcurrent Protection Integrated
AC Short Circuit Protection Integrated
AC Overvoltage Protection Integrated
DC Switch Integrated
DC Surge Protection Type II
AC Surge Protection Type II
AFCI Integrated
Rapid Shutdown Optional
Remote Shutdown Integrated
General Data
Operating Temperature Range (°C) -35 ~ +60
Relative Humidity 0 ~ 95%
Max. Operating Altitude (m) 3000
Cooling Method Natural Cooling                                                   Smart Fan Cooling                                                Smart Fan Cooling
User Interface LCD, WLAN + APP
Communication with BMS CAN
Communication RS485, WiFi + LAN+Bluetooth
Communication Protocols Modbus-RTU, Modbus-TCP
Weight (kg) 26.4                                                                          27.3                                                                          28.9
Dimension (W × H × D mm) 561 × 445 × 230
Noise Emission (dB) <35                                                                          <45                                                                          <45
Ingress Protection Rating IP66
Anti-corrosion Class C4
Mounting Method Wall Mounted