
MP-X3-IES 4-15kW 3 Phase All-in-one Residential ESS-5743
The China Moneypro X3‑IES Series is a three‑phase all‑in‑one residential energy storage system that integrates a hybrid solar inverter, intelligent energy management, and expandable battery modules into a streamlined solution. Designed for both on‑grid and backup scenarios, it maximizes solar self‑consumption, supports flexible PV integration, and provides robust backup power with high reliability and safety.
Smart, Integrated Solar + Storage for Modern Homes
The China Moneypro X3‑IES Series is a three‑phase all‑in‑one residential energy storage system that integrates a hybrid solar inverter, intelligent energy management, and expandable battery modules into a streamlined solution. Designed for both on‑grid and backup scenarios, it maximizes solar self‑consumption, supports flexible PV integration, and provides robust backup power with high reliability and safety.
High Yield & Efficient Energy Harvest
Capture More Solar, Use More Power
-
Supports up to 200 % PV oversizing for larger PV arrays relative to inverter power.
-
DC input current up to 20 A per MPPT (higher on larger variants) helps capture high‑power PV modules.
-
Low startup voltage and global MPP scan enhance power harvest throughout the day.
-
High charge/discharge capability (up to ~50 A) ensures responsive energy cycling.
Benefits:
-
More effective daily solar capture for higher self‑consumption.
-
Works well with diverse rooftop orientations and high‑wattage panels.
Reliable Backup & Seamless Power Delivery
Power Continuity When You Need It
-
UPS‑level switchover < 10 ms keeps critical loads running without interruption.
-
EPS output rated at full inverter power with peak overload up to 200 % for 10 s, supporting transient heavy loads.
-
Integrated system can operate in on‑grid, off‑grid, or hybrid modes depending on configuration.
Advantages:
-
Smooth transition between grid and backup power during outages.
-
Flexibility to handle short bursts of high load.
Smart Energy Management
Intelligent, Connected & Adaptive
-
AI‑driven energy management forecasts solar generation and load for optimized usage.
-
VPP‑ready support allows participation in grid flexibility programs (OpenADR, IEEE2030.5).
-
Smart load scheduling and TOU (time‑of‑use) strategies improve cost efficiency.
-
Remote monitoring via cloud provides system insights and performance data.
Benefits:
-
Maximize solar self‑consumption and minimize grid reliance.
-
Intelligent control adapts to tariff and load patterns.
Safe, Durable & Outdoor‑Ready
Built for Everyday Reliability
-
IP66 ingress protection guards against dust and water for sheltered outdoor installation.
-
Multi‑layer safety with optional AFCI and Type II SPD increases system protection.
-
LFP (lithium iron phosphate) battery compatibility offers stable and long life operation.
Advantages:
-
Strong design ensures durability across environments.
-
Multiple safety layers protect both system and home.
Why Choose China Moneypro X3‑IES?
-
Integrated All‑in‑One: Combines hybrid inverter, BMS, and energy storage modules for simplicity.
-
Efficient Solar Use: Up to 200 % PV oversizing and high DC input capture more solar energy.
-
Reliable Backup: Fast switchover and EPS overload support enhance power continuity.
-
Smart Energy Control: AI‑driven system and VPP readiness provide advanced energy management.
-
Durable & Safe: IP66 protection with advanced safety options ensures long‑term reliability.
Key Specifications (Representative Models)
| Model | Max. PV Array Power | MPPT Count | Rated Output Power | EPS Output | Switchover Time | Protection |
|---|---|---|---|---|---|---|
| X3‑IES‑4K | 8 kWp | 2 | 4 kVA | 4 kVA | < 10 ms | IP66 |
| X3‑IES‑5K | 10 kWp | 2 | 5 kVA | 5 kVA | < 10 ms | IP66 |
| X3‑IES‑6K | 12 kWp | 2 | 6 kVA | 6 kVA | < 10 ms | IP66 |
| X3‑IES‑8K | 16 kWp | 2 | 8 kVA | 8 kVA | < 10 ms | IP66 |
| X3‑IES‑10K | 20 kWp | 2 | 10 kVA | 10 kVA | < 10 ms | IP66 |
| X3‑IES‑12K | 24 kWp | 2 | 12 kVA | 12 kVA | < 10 ms | IP66 |
| X3‑IES‑15K | 30 kWp | 2 | 15 kVA | 15 kVA | < 10 ms | IP66 |
Numbers above are typical values; exact specs vary by regional configuration.
Typical Applications
-
Residential Rooftops: Integrated solar + storage for daily energy use.
-
Backup Power Support: Keep essential circuits powered during grid outages.
-
Tariff Optimization: Minimize energy bills with smart TOU strategies.
-
Smart Homes: Connect with EV chargers and smart loads for enhanced control.
FAQ – Common Questions
Q1: What power ratings are available in the X3‑IES series?
It covers 4 kW to 15 kW output variants for diverse household and small commercial needs.
Q2: How quickly does it switch to backup power?
The system offers UPS‑level switchover in < 10 ms.
Q3: Can it handle large PV arrays?
Yes — supports up to 200 % PV oversizing to maximize solar capture.
Q4: Is it suitable for outdoor installation?
With IP66 protection, it can be installed in sheltered outdoor environments.
Q5: What safety protections are included?
Safety features include optional AFCI and AC/DC Type II SPD protection.
Specifications
|
Technical Data
|
X3-IES-4K
|
X3-IES-5K
|
X3-IES-6K
|
X3-IES-8K
|
X3-IES-10K
|
X3-IES-12K
|
X3-IES-15K
|
|---|---|---|---|---|---|---|---|
|
System Overview
|
|||||||
|
Rated output power
|
4 kW
|
5 kW
|
6 kW
|
8 kW
|
10 kW
|
12 kW
|
15 kW
|
|
Number of batteries
|
2
|
3
|
4
|
5
|
6
|
5
|
6
|
|
Nominal capacity
|
10.2 kWh
|
15.3 kWh
|
20.4 kWh
|
25.6 kWh
|
30.7 kWh
|
25.6 kWh
|
30.7 kWh
|
|
Usable energy
|
9.2 kWh
|
13.8 kWh
|
18.4 kWh
|
23.0 kWh
|
27.6 kWh
|
23.0 kWh
|
27.6 kWh
|
|
Max. charge / discharge power
|
10.2 kW
|
15.0 kW
|
15.0 kW
|
15.0 kW
|
15.0 kW
|
15.0 kW
|
15.0 kW
|
|
Degree of protection
|
IP66
|
IP66
|
IP66
|
IP66
|
IP66
|
IP66
|
IP66
|
|
Operating temperature range
|
-30 ~ 53°C
|
-30 ~ 53°C
|
-30 ~ 53°C
|
-30 ~ 53°C
|
-30 ~ 53°C
|
-30 ~ 53°C
|
-30 ~ 53°C
|
|
Allowable relative humidity range
|
4 ~ 100% (condensing)
|
4 ~ 100% (condensing)
|
4 ~ 100% (condensing)
|
4 ~ 100% (condensing)
|
4 ~ 100% (condensing)
|
4 ~ 100% (condensing)
|
4 ~ 100% (condensing)
|
|
Max. operating altitude
|
3000 m
|
3000 m
|
3000 m
|
3000 m
|
3000 m
|
3000 m
|
3000 m
|
|
Net weight
|
147.2 kg
|
194.2 kg
|
241.2 kg
|
147.2 / 146.2 kg
|
194.2 / 146.2 kg
|
147.2 / 146.2 kg
|
194.2 / 146.2 kg
|
|
Dimension (W × H × D)
|
730 × 1281 × 209.5 mm
|
730 × 1599 × 209.5 mm
|
730 × 1917 × 209.5 mm
|
730 × 1281 × 209.5 mm / 730 × 1120.5 × 150 mm
|
730 × 1599 × 209.5 mm / 730 × 1120.5 × 150 mm
|
730 × 1281 × 209.5 mm / 730 × 1120.5 × 150 mm
|
730 × 1599 × 209.5 mm / 730 × 1120.5 × 150 mm
|
|
Display
|
LCD
|
LCD
|
LCD
|
LCD
|
LCD
|
LCD
|
LCD
|
|
Cooling concept
|
Natural cooling
|
Natural cooling
|
Natural cooling
|
Natural cooling
|
Natural cooling
|
Natural cooling
|
Natural cooling
|
|
Topology
|
Non-isolated
|
Non-isolated
|
Non-isolated
|
Non-isolated
|
Non-isolated
|
Non-isolated
|
Non-isolated
|
|
Communication
|
RS485, Pocket-X, USB, CAN, DO, DI
|
RS485, Pocket-X, USB, CAN, DO, DI
|
RS485, Pocket-X, USB, CAN, DO, DI
|
RS485, Pocket-X, USB, CAN, DO, DI
|
RS485, Pocket-X, USB, CAN, DO, DI
|
RS485, Pocket-X, USB, CAN, DO, DI
|
RS485, Pocket-X, USB, CAN, DO, DI
|
|
PV Input
|
|||||||
|
Max. recommended PV array power
|
8 kWp
|
10 kWp
|
12 kWp
|
16 kWp
|
20 kWp
|
24 kWp
|
30 kWp
|
|
Max. PV input voltage
|
1000 V
|
1000 V
|
1000 V
|
1000 V
|
1000 V
|
1000 V
|
1000 V
|
|
Nominal PV input voltage
|
600 V
|
600 V
|
600 V
|
600 V
|
600 V
|
600 V
|
600 V
|
|
Operating voltage range
|
90 ~ 950 V
|
90 ~ 950 V
|
90 ~ 950 V
|
90 ~ 950 V
|
90 ~ 950 V
|
90 ~ 950 V
|
90 ~ 950 V
|
|
MPPT voltage range
|
110 ~ 950 V
|
110 ~ 950 V
|
110 ~ 950 V
|
110 ~ 950 V
|
110 ~ 950 V
|
110 ~ 950 V
|
110 ~ 950 V
|
|
Start-up voltage
|
140 V
|
140 V
|
140 V
|
140 V
|
140 V
|
140 V
|
140 V
|
|
No. of MPP trackers / Strings per MPP tracker
|
2 / (1/1)
|
2 / (1/1)
|
2 / (1/1)
|
3 / (1/1/1)
|
3 / (1/1/1)
|
3 / (1/1/1)
|
3 / (1/1/1)
|
|
Max. input current per MPPT (MPPT1/2/3)
|
20 A / 20 A
|
20 A / 20 A
|
20 A / 20 A
|
20 A / 20 A / 20 A
|
20 A / 20 A / 20 A
|
20 A / 20 A / 20 A
|
20 A / 20 A / 20 A
|
|
Max. input short circuit current per MPPT
|
25 A / 25 A
|
25 A / 25 A
|
25 A / 25 A
|
25 A / 25 A / 25 A
|
25 A / 25 A / 25 A
|
25 A / 25 A / 25 A
|
25 A / 25 A / 25 A
|
|
AC Input & Output (On-Grid)
|
|||||||
|
Rated output power
|
4 kW
|
5 kW
|
6 kW
|
8 kW
|
10 kW
|
12 kW
|
15 kW
|
|
Rated output current
|
5.8 A
|
7.3 A
|
8.7 A
|
11.6 A
|
14.5 A
|
17.4 A
|
21.8 A
|
|
Max. output apparent power
|
4000 VA
|
5500 VA
|
6600 VA
|
8800 VA
|
10000 VA
|
13200 VA
|
16500 VA
|
|
Max. output continuous current
|
6.1 A
|
8.4 A
|
10 A
|
13.4 A
|
15.2 A
|
20.0 A
|
25.0 A
|
|
Nominal AC voltage
|
3/N/PE, 220 / 380 V; 3/N/PE, 230 / 400 V
|
3/N/PE, 220 / 380 V; 3/N/PE, 230 / 400 V
|
3/N/PE, 220 / 380 V; 3/N/PE, 230 / 400 V
|
3/N/PE, 220 / 380 V; 3/N/PE, 230 / 400 V
|
3/N/PE, 220 / 380 V; 3/N/PE, 230 / 400 V
|
3/N/PE, 220 / 380 V; 3/N/PE, 230 / 400 V
|
3/N/PE, 220 / 380 V; 3/N/PE, 230 / 400 V
|
|
Max. input apparent power
|
10 kVA
|
10 kVA
|
12 kVA
|
16 kVA
|
20 kVA
|
20 kVA
|
20 kVA
|
|
Max. AC input current
|
16.1 A
|
16.1 A
|
19.3 A
|
25.8 A
|
32.0 A
|
32.0 A
|
32.0 A
|
|
Nominal AC frequency
|
50 Hz / 60 Hz
|
50 Hz / 60 Hz
|
50 Hz / 60 Hz
|
50 Hz / 60 Hz
|
50 Hz / 60 Hz
|
50 Hz / 60 Hz
|
50 Hz / 60 Hz
|
|
AC frequency range
|
50 ± 5 Hz / 60 ± 5 Hz
|
50 ± 5 Hz / 60 ± 5 Hz
|
50 ± 5 Hz / 60 ± 5 Hz
|
50 ± 5 Hz / 60 ± 5 Hz
|
50 ± 5 Hz / 60 ± 5 Hz
|
50 ± 5 Hz / 60 ± 5 Hz
|
50 ± 5 Hz / 60 ± 5 Hz
|
|
Adjustable power factor range
|
~1 (0.8 lagging to 0.8 leading)
|
~1 (0.8 lagging to 0.8 leading)
|
~1 (0.8 lagging to 0.8 leading)
|
~1 (0.8 lagging to 0.8 leading)
|
~1 (0.8 lagging to 0.8 leading)
|
~1 (0.8 lagging to 0.8 leading)
|
~1 (0.8 lagging to 0.8 leading)
|
|
THDi (rated power)
|
<3%
|
<3%
|
<3%
|
<3%
|
<3%
|
<3%
|
<3%
|
|
Battery
|
|||||||
|
Battery voltage range
|
160 ~ 800 V
|
160 ~ 800 V
|
160 ~ 800 V
|
160 ~ 800 V
|
160 ~ 800 V
|
160 ~ 800 V
|
160 ~ 800 V
|
|
Communication interfaces
|
CAN / RS485
|
CAN / RS485
|
CAN / RS485
|
CAN / RS485
|
CAN / RS485
|
CAN / RS485
|
CAN / RS485
|
|
BMS module
|
TBMS-MCS0800E
|
TBMS-MCS0800E
|
TBMS-MCS0800E
|
TBMS-MCS0800E
|
TBMS-MCS0800E
|
TBMS-MCS0800E
|
TBMS-MCS0800E
|
|
Battery module
|
TP-HS50E
|
TP-HS50E
|
TP-HS50E
|
TP-HS50E
|
TP-HS50E
|
TP-HS50E
|
TP-HS50E
|
|
Composition
|
TBMS-MCS0800E + TP-HS50E × n + Base Dimensions + Series Box (Required for two columns)
|
TBMS-MCS0800E + TP-HS50E × n + Base Dimensions + Series Box (Required for two columns)
|
TBMS-MCS0800E + TP-HS50E × n + Base Dimensions + Series Box (Required for two columns)
|
TBMS-MCS0800E + TP-HS50E × n + Base Dimensions + Series Box (Required for two columns)
|
TBMS-MCS0800E + TP-HS50E × n + Base Dimensions + Series Box (Required for two columns)
|
TBMS-MCS0800E + TP-HS50E × n + Base Dimensions + Series Box (Required for two columns)
|
TBMS-MCS0800E + TP-HS50E × n + Base Dimensions + Series Box (Required for two columns)
|
|
Battery type
|
LFP
|
LFP
|
LFP
|
LFP
|
LFP
|
LFP
|
LFP
|
|
Nominal capacity / Nominal capacity
|
5.1 kWh / 50 Ah
|
5.1 kWh / 50 Ah
|
5.1 kWh / 50 Ah
|
5.1 kWh / 50 Ah
|
5.1 kWh / 50 Ah
|
5.1 kWh / 50 Ah
|
5.1 kWh / 50 Ah
|
|
Usable energy
|
4.6 kWh
|
4.6 kWh
|
4.6 kWh
|
4.6 kWh
|
4.6 kWh
|
4.6 kWh
|
4.6 kWh
|
|
Standard power
|
3 kW
|
3 kW
|
3 kW
|
3 kW
|
3 kW
|
3 kW
|
3 kW
|
|
Max power
|
5.1 kW
|
5.1 kW
|
5.1 kW
|
5.1 kW
|
5.1 kW
|
5.1 kW
|
5.1 kW
|
|
Max. charge/discharge current
|
50 A
|
50 A
|
50 A
|
50 A
|
50 A
|
50 A
|
50 A
|
|
Cycle life
|
>6000 cycles
|
>6000 cycles
|
>6000 cycles
|
>6000 cycles
|
>6000 cycles
|
>6000 cycles
|
>6000 cycles
|
|
Warranty
|
10 years
|
10 years
|
10 years
|
10 years
|
10 years
|
10 years
|
10 years
|
|
Safety
|
CE, RCM, TUV (IEC62619), ROHS, REACH
|
CE, RCM, TUV (IEC62619), ROHS, REACH
|
CE, RCM, TUV (IEC62619), ROHS, REACH
|
CE, RCM, TUV (IEC62619), ROHS, REACH
|
CE, RCM, TUV (IEC62619), ROHS, REACH
|
CE, RCM, TUV (IEC62619), ROHS, REACH
|
CE, RCM, TUV (IEC62619), ROHS, REACH
|
|
TBMS-MCS0800E dimensions (W × H × D) / Weight
|
730 × 165 × 150 mm / 9.3 kg
|
730 × 165 × 150 mm / 9.3 kg
|
730 × 165 × 150 mm / 9.3 kg
|
730 × 165 × 150 mm / 9.3 kg
|
730 × 165 × 150 mm / 9.3 kg
|
730 × 165 × 150 mm / 9.3 kg
|
730 × 165 × 150 mm / 9.3 kg
|
|
TP-HS50E dimensions (W × H × D) / Weight
|
730 × 318 × 150 mm / 47 kg
|
730 × 318 × 150 mm / 47 kg
|
730 × 318 × 150 mm / 47 kg
|
730 × 318 × 150 mm / 47 kg
|
730 × 318 × 150 mm / 47 kg
|
730 × 318 × 150 mm / 47 kg
|
730 × 318 × 150 mm / 47 kg
|
|
Base dimensions (W × H × D) / Weight
|
730 × 75 × 150 mm / 3.9 kg
|
730 × 75 × 150 mm / 3.9 kg
|
730 × 75 × 150 mm / 3.9 kg
|
730 × 75 × 150 mm / 3.9 kg
|
730 × 75 × 150 mm / 3.9 kg
|
730 × 75 × 150 mm / 3.9 kg
|
730 × 75 × 150 mm / 3.9 kg
|
|
Series box dimensions (W × H × D) / Weight
|
167 × 91.5 × 121 mm / 1.3 kg
|
167 × 91.5 × 121 mm / 1.3 kg
|
167 × 91.5 × 121 mm / 1.3 kg
|
167 × 91.5 × 121 mm / 1.3 kg
|
167 × 91.5 × 121 mm / 1.3 kg
|
167 × 91.5 × 121 mm / 1.3 kg
|
167 × 91.5 × 121 mm / 1.3 kg
|
|
EPS (Off-Grid) Output (With Battery)
|
|||||||
|
Rated EPS output voltage, frequency
|
230 V / 400 V, 50 Hz / 60 Hz
|
230 V / 400 V, 50 Hz / 60 Hz
|
230 V / 400 V, 50 Hz / 60 Hz
|
230 V / 400 V, 50 Hz / 60 Hz
|
230 V / 400 V, 50 Hz / 60 Hz
|
230 V / 400 V, 50 Hz / 60 Hz
|
230 V / 400 V, 50 Hz / 60 Hz
|
|
Rated EPS output power
|
4 kVA
|
5 kVA
|
6 kVA
|
8 kVA
|
10 kVA
|
12 kVA
|
15 kVA
|
|
Peak EPS output power
|
2 times of rated power, 10 s
|
2 times of rated power, 10 s
|
2 times of rated power, 10 s
|
2 times of rated power, 10 s
|
2 times of rated power, 10 s
|
2 times of rated power, 10 s
|
2 times of rated power, 10 s
|
|
Switchover time
|
< 10 ms
|
< 10 ms
|
< 10 ms
|
< 10 ms
|
< 10 ms
|
< 10 ms
|
< 10 ms
|
|
Efficiency
|
|||||||
|
Max. efficiency
|
98.0%
|
98.0%
|
98.0%
|
98.0%
|
98.0%
|
98.0%
|
98.0%
|
|
European efficiency
|
97.7%
|
97.7%
|
97.7%
|
97.7%
|
97.7%
|
97.7%
|
97.7%
|
|
Environment Limit
|
|||||||
|
Ingress protection
|
IP66
|
IP66
|
IP66
|
IP66
|
IP66
|
IP66
|
IP66
|
|
Operating ambient temperature range
|
-35 ~ 60°C
|
-35 ~ 60°C
|
-35 ~ 60°C
|
-35 ~ 60°C
|
-35 ~ 60°C
|
-35 ~ 60°C
|
-35 ~ 60°C
|
|
Max. operating altitude
|
3000 m
|
3000 m
|
3000 m
|
3000 m
|
3000 m
|
3000 m
|
3000 m
|
|
Relative humidity
|
4 ~ 100% RH (condensing)
|
4 ~ 100% RH (condensing)
|
4 ~ 100% RH (condensing)
|
4 ~ 100% RH (condensing)
|
4 ~ 100% RH (condensing)
|
4 ~ 100% RH (condensing)
|
4 ~ 100% RH (condensing)
|
|
Overvoltage Category
|
Mains: I, Battery: II, PV: II
|
Mains: I, Battery: II, PV: II
|
Mains: I, Battery: II, PV: II
|
Mains: I, Battery: II, PV: II
|
Mains: I, Battery: II, PV: II
|
Mains: I, Battery: II, PV: II
|
Mains: I, Battery: II, PV: II
|
|
General
|
|||||||
|
Dimensions (W × H × D)
|
717 × 405 × 209.5 mm
|
717 × 405 × 209.5 mm
|
717 × 405 × 209.5 mm
|
717 × 405 × 209.5 mm
|
717 × 405 × 209.5 mm
|
717 × 405 × 209.5 mm
|
717 × 405 × 209.5 mm
|
|
Net weight
|
40 kg
|
40 kg
|
40 kg
|
40 kg
|
40 kg
|
40 kg
|
40 kg
|
|
Cooling concept
|
Natural cooling
|
Natural cooling
|
Natural cooling
|
Natural cooling
|
Natural cooling
|
Natural cooling
|
Natural cooling
|
|
Communication interfaces
|
RS485, Pocket-X, CAN + RS485, DO, DI
|
RS485, Pocket-X, CAN + RS485, DO, DI
|
RS485, Pocket-X, CAN + RS485, DO, DI
|
RS485, Pocket-X, CAN + RS485, DO, DI
|
RS485, Pocket-X, CAN + RS485, DO, DI
|
RS485, Pocket-X, CAN + RS485, DO, DI
|
RS485, Pocket-X, CAN + RS485, DO, DI
|
|
Power consumption (night)
|
< 40 W for hot standby, < 5 W for cold standby
|
< 40 W for hot standby, < 5 W for cold standby
|
< 40 W for hot standby, < 5 W for cold standby
|
< 40 W for hot standby, < 5 W for cold standby
|
< 40 W for hot standby, < 5 W for cold standby
|
< 40 W for hot standby, < 5 W for cold standby
|
< 40 W for hot standby, < 5 W for cold standby
|
|
Topology
|
Non-isolated
|
Non-isolated
|
Non-isolated
|
Non-isolated
|
Non-isolated
|
Non-isolated
|
Non-isolated
|
|
Certificates and approvals
|
IEC62109-1 / IEC62109-2, VDE 0126-1-1 A1:2012 / VDE-AR-N 4105 / G98 / G99 / AS4777 / EN50549 / CEI 0-21
|
IEC62109-1 / IEC62109-2, VDE 0126-1-1 A1:2012 / VDE-AR-N 4105 / G98 / G99 / AS4777 / EN50549 / CEI 0-21
|
IEC62109-1 / IEC62109-2, VDE 0126-1-1 A1:2012 / VDE-AR-N 4105 / G98 / G99 / AS4777 / EN50549 / CEI 0-21
|
IEC62109-1 / IEC62109-2, VDE 0126-1-1 A1:2012 / VDE-AR-N 4105 / G98 / G99 / AS4777 / EN50549 / CEI 0-21
|
IEC62109-1 / IEC62109-2, VDE 0126-1-1 A1:2012 / VDE-AR-N 4105 / G98 / G99 / AS4777 / EN50549 / CEI 0-21
|
IEC62109-1 / IEC62109-2, VDE 0126-1-1 A1:2012 / VDE-AR-N 4105 / G98 / G99 / AS4777 / EN50549 / CEI 0-21
|
IEC62109-1 / IEC62109-2, VDE 0126-1-1 A1:2012 / VDE-AR-N 4105 / G98 / G99 / AS4777 / EN50549 / CEI 0-21
|
|
AC auxiliary power supply (APS)
|
Built-in
|
Built-in
|
Built-in
|
Built-in
|
Built-in
|
Built-in
|
Built-in
|
|
Protection
|
|||||||
|
Protections
|
Overvoltage protection, Undervoltage protection, Overfrequency protection, Underfrequency protection, Residual current detection, Over-temperature protection, DC isolation protection, Grid monitoring, DC injection monitoring, Back feed current protection
|
Overvoltage protection, Undervoltage protection, Overfrequency protection, Underfrequency protection, Residual current detection, Over-temperature protection, DC isolation protection, Grid monitoring, DC injection monitoring, Back feed current protection
|
Overvoltage protection, Undervoltage protection, Overfrequency protection, Underfrequency protection, Residual current detection, Over-temperature protection, DC isolation protection, Grid monitoring, DC injection monitoring, Back feed current protection
|
Overvoltage protection, Undervoltage protection, Overfrequency protection, Underfrequency protection, Residual current detection, Over-temperature protection, DC isolation protection, Grid monitoring, DC injection monitoring, Back feed current protection
|
Overvoltage protection, Undervoltage protection, Overfrequency protection, Underfrequency protection, Residual current detection, Over-temperature protection, DC isolation protection, Grid monitoring, DC injection monitoring, Back feed current protection
|
Overvoltage protection, Undervoltage protection, Overfrequency protection, Underfrequency protection, Residual current detection, Over-temperature protection, DC isolation protection, Grid monitoring, DC injection monitoring, Back feed current protection
|
Overvoltage protection, Undervoltage protection, Overfrequency protection, Underfrequency protection, Residual current detection, Over-temperature protection, DC isolation protection, Grid monitoring, DC injection monitoring, Back feed current protection
|
|
Active anti-islanding method
|
Frequency shift
|
Frequency shift
|
Frequency shift
|
Frequency shift
|
Frequency shift
|
Frequency shift
|
Frequency shift
|
|
Surge protection (DC / AC)
|
DC: Type II, AC: Type II
|
DC: Type II, AC: Type II
|
DC: Type II, AC: Type II
|
DC: Type II, AC: Type II
|
DC: Type II, AC: Type II
|
DC: Type II, AC: Type II
|
DC: Type II, AC: Type II
|
|
Arc-fault circuit interrupter (AFCI)
|
Optional
|
Optional
|
Optional
|
Optional
|
Optional
|
Optional
|
Optional
|



