MP-BAT-S Series 25.6 ?C 56.3kWh High Voltage Lithium Battery-1318
Designed for commercial and industrial (C&I) applications, the China Moneypro BAT‑S Series is a high‑voltage lithium battery system engineered to provide large‑capacity energy storage, strong safety performance, and flexible expandability. Its modular rack architecture supports stacking of multiple battery packs, making it ideal for projects requiring scalable storage solutions with dependable long‑term operation.
Reliable & Scalable Energy Storage
Designed for commercial and industrial (C&I) applications, the China Moneypro BAT‑S Series is a high‑voltage lithium battery system engineered to provide large‑capacity energy storage, strong safety performance, and flexible expandability. Its modular rack architecture supports stacking of multiple battery packs, making it ideal for projects requiring scalable storage solutions with dependable long‑term operation.
High Performance & Flexible Expansion
Modular Design for Capacity Growth
-
Supports 5–11 battery pack stacking per system, enabling customized capacity configurations to match diverse energy demands.
-
Up to 6 battery racks in parallel can be integrated, providing very high total capacity for large installations.
-
Flexible rack design simplifies transportation and installation on‑site.
Benefits:
-
Expand storage capacity as energy requirements grow.
-
Adaptable to different system sizes and project specifications.
Superb Safety & Durability
Engineered for Long‑Lasting Use
-
Uses LFP (Lithium Iron Phosphate) battery cells, known for high cycle stability and inherent safety.
-
Optional aerosol‑based fire suppression system at the pack level enhances fire risk protection and overall system safety.
-
IP20 protection rating ensures reliable resistance against dust and impacts in controlled environments.
Benefits:
-
Safe operation with reduced risk of thermal runaway.
-
Proven durability for commercial environments with high performance expectations.
Smart Control & Monitoring
Intelligent System Management
-
Battery system supports remote monitoring and control for streamlined O&M (operations and maintenance).
-
Automatic reboot after undervoltage events improves resilience and system stability.
-
Modular architecture facilitates simpler upgrades and maintenance compared to fixed‑capacity systems.
Advantages:
-
Reduced onsite intervention for diagnostics and updates.
-
Enhanced reliability with automatic fault recovery.
Why Choose China Moneypro BAT‑S Series?
-
Flexible Capacity: Modular stacking from 25.6 kWh up to 56.3 kWh per rack and more with parallel deployment.
-
Scalable Expansion: Supports multiple racks in parallel for large‑scale storage needs.
-
Safe & Reliable: LFP cells and optional fire suppression for comprehensive protection.
-
Smart Monitoring: Remote O&M and automatic reboot improve system uptime.
-
Modular & Easy to Install: Rack design simplifies transport, installation, and future upgrades.
Key Specifications
| Model | Usable Energy | Nominal Voltage | Max. Charge / Discharge Current | Protection |
|---|---|---|---|---|
| BAT‑25.6 | ~25 kWh | 256 V | ~100 / 110 A | IP20 |
| BAT‑30.7 | ~30 kWh | 307.2 V | ~100 / 110 A | IP20 |
| BAT‑35.8 | ~35 kWh | 358.4 V | ~100 / 110 A | IP20 |
| BAT‑40.9 | ~40 kWh | 409.6 V | ~100 / 110 A | IP20 |
| BAT‑46.0 | ~45 kWh | 460.8 V | ~100 / 110 A | IP20 |
| BAT‑51.2 | ~50 kWh | 512 V | ~100 / 110 A | IP20 |
| BAT‑56.3 | ~55 kWh | 563.2 V | ~100 / 110 A | IP20 |
| *Values are rounded nominal figures for typical configurations. |
Typical Applications
-
Commercial Solar + Storage: Provides substantial energy capacity for business peak load management and self‑consumption optimization.
-
Industrial Backup Power: Ensures reliable power support during grid interruptions for critical loads.
-
Energy Cost Optimization: Helps reduce peak demand charges and manage energy usage proactively.
-
Large‑Scale Hybrid Systems: Works with high‑voltage hybrid inverters for flexible PV + storage integration.
FAQ – Common Questions
Q1: What capacity options are available in the BAT‑S Series?
The series offers modular battery packs from ~25.6 kWh up to ~56.3 kWh, which can be combined across multiple racks for larger systems.
Q2: What type of battery cells are used?
It uses LFP (Lithium Iron Phosphate) cells known for high safety and cycle stability.
Q3: Can multiple BAT‑S units be connected together?
Yes — up to 6 battery racks can be paralleled to achieve very high storage capacities.
Q4: Is the system suitable for commercial energy storage use?
Absolutely — it’s designed specifically for C&I applications such as peak shaving, backup power, and load management.
Q5: How is maintenance and monitoring handled?
The system supports remote monitoring and control, along with automatic fault recovery to ease O&M.
Specifications
|
Technical Data
|
BAT25
|
BAT30
|
BAT35
|
BAT40
|
BAT45
|
BAT50
|
BAT56
|
|---|---|---|---|---|---|---|---|
|
Input
|
|||||||
|
Nominal Voltage (V)
|
204.8
|
204.8
|
204.8
|
204.8
|
204.8
|
204.8
|
204.8
|
|
Operating Voltage Range (V)
|
180 ~ 228
|
180 ~ 228
|
180 ~ 228
|
180 ~ 228
|
180 ~ 228
|
180 ~ 228
|
180 ~ 228
|
|
Nominal Capacity (Ah)
|
125
|
150
|
175
|
200
|
225
|
250
|
275
|
|
Nominal Energy (kWh)
|
25.6
|
30.7
|
35.8
|
41.0
|
46.1
|
51.2
|
56.3
|
|
Usable Energy (90% DOD, kWh)
|
23.0
|
27.6
|
32.2
|
36.9
|
41.5
|
46.1
|
50.7
|
|
Max. Charge / Discharge Current (A)
|
50 / 50
|
50 / 50
|
50 / 50
|
50 / 50
|
50 / 50
|
50 / 50
|
50 / 50
|
|
Max. Charge / Discharge Power (kW)
|
10.24 / 10.24
|
10.24 / 10.24
|
10.24 / 10.24
|
10.24 / 10.24
|
10.24 / 10.24
|
10.24 / 10.24
|
10.24 / 10.24
|
|
Depth of Discharge
|
90%
|
90%
|
90%
|
90%
|
90%
|
90%
|
90%
|
|
Efficiency
|
|||||||
|
Battery Roundtrip Efficiency (25°C)
|
95%
|
95%
|
95%
|
95%
|
95%
|
95%
|
95%
|
|
Cycle Life & Warranty
|
|||||||
|
Cycle Life (90% DOD, 25°C)
|
> 6000 cycles
|
> 6000 cycles
|
> 6000 cycles
|
> 6000 cycles
|
> 6000 cycles
|
> 6000 cycles
|
> 6000 cycles
|
|
Warranty
|
10 Years
|
10 Years
|
10 Years
|
10 Years
|
10 Years
|
10 Years
|
10 Years
|
|
Scalability
|
2 ~ 8 modules in parallel
|
2 ~ 8 modules in parallel
|
2 ~ 8 modules in parallel
|
2 ~ 8 modules in parallel
|
2 ~ 8 modules in parallel
|
2 ~ 8 modules in parallel
|
2 ~ 8 modules in parallel
|
|
Environmental Requirements
|
|||||||
|
Operating Temperature – Charge (°C)
|
0 ~ +55
|
0 ~ +55
|
0 ~ +55
|
0 ~ +55
|
0 ~ +55
|
0 ~ +55
|
0 ~ +55
|
|
Operating Temperature – Discharge (°C)
|
-20 ~ +55
|
-20 ~ +55
|
-20 ~ +55
|
-20 ~ +55
|
-20 ~ +55
|
-20 ~ +55
|
-20 ~ +55
|
|
Storage Temperature – 1~3 months (°C)
|
-20 ~ +45
|
-20 ~ +45
|
-20 ~ +45
|
-20 ~ +45
|
-20 ~ +45
|
-20 ~ +45
|
-20 ~ +45
|
|
Storage Temperature – 3~6 months (°C)
|
-20 ~ +35
|
-20 ~ +35
|
-20 ~ +35
|
-20 ~ +35
|
-20 ~ +35
|
-20 ~ +35
|
-20 ~ +35
|
|
Storage Temperature – 6~12 months (°C)
|
-20 ~ +30
|
-20 ~ +30
|
-20 ~ +30
|
-20 ~ +30
|
-20 ~ +30
|
-20 ~ +30
|
-20 ~ +30
|
|
Relative Humidity
|
5 ~ 95% RH (non-condensing)
|
5 ~ 95% RH (non-condensing)
|
5 ~ 95% RH (non-condensing)
|
5 ~ 95% RH (non-condensing)
|
5 ~ 95% RH (non-condensing)
|
5 ~ 95% RH (non-condensing)
|
5 ~ 95% RH (non-condensing)
|
|
Max. Operating Altitude (m)
|
< 3000
|
< 3000
|
< 3000
|
< 3000
|
< 3000
|
< 3000
|
< 3000
|
|
Cooling Method
|
Natural cooling
|
Natural cooling
|
Natural cooling
|
Natural cooling
|
Natural cooling
|
Natural cooling
|
Natural cooling
|
|
Environment
|
Indoor
|
Indoor
|
Indoor
|
Indoor
|
Indoor
|
Indoor
|
Indoor
|
|
Ingress Protection Rating
|
IP20
|
IP20
|
IP20
|
IP20
|
IP20
|
IP20
|
IP20
|
|
Installation Type
|
Rack mounting
|
Rack mounting
|
Rack mounting
|
Rack mounting
|
Rack mounting
|
Rack mounting
|
Rack mounting
|
|
Communication & Interface
|
|||||||
|
Display
|
LED Indicators
|
LED Indicators
|
LED Indicators
|
LED Indicators
|
LED Indicators
|
LED Indicators
|
LED Indicators
|
|
Communication Interfaces
|
CAN / RS485
|
CAN / RS485
|
CAN / RS485
|
CAN / RS485
|
CAN / RS485
|
CAN / RS485
|
CAN / RS485
|
|
Communication Protocol
|
Modbus-RTU
|
Modbus-RTU
|
Modbus-RTU
|
Modbus-RTU
|
Modbus-RTU
|
Modbus-RTU
|
Modbus-RTU
|
|
Protection & Safety
|
|||||||
|
Protection Features
|
Overcharge/Over-discharge Protection, Overcurrent Protection, Short Circuit Protection, Over-temperature Protection, Insulation Detection
|
Overcharge/Over-discharge Protection, Overcurrent Protection, Short Circuit Protection, Over-temperature Protection, Insulation Detection
|
Overcharge/Over-discharge Protection, Overcurrent Protection, Short Circuit Protection, Over-temperature Protection, Insulation Detection
|
Overcharge/Over-discharge Protection, Overcurrent Protection, Short Circuit Protection, Over-temperature Protection, Insulation Detection
|
Overcharge/Over-discharge Protection, Overcurrent Protection, Short Circuit Protection, Over-temperature Protection, Insulation Detection
|
Overcharge/Over-discharge Protection, Overcurrent Protection, Short Circuit Protection, Over-temperature Protection, Insulation Detection
|
Overcharge/Over-discharge Protection, Overcurrent Protection, Short Circuit Protection, Over-temperature Protection, Insulation Detection
|
|
Surge Protection
|
Integrated
|
Integrated
|
Integrated
|
Integrated
|
Integrated
|
Integrated
|
Integrated
|
|
Mechanical Parameters
|
|||||||
|
Dimensions (W × H × D mm)
|
442 × 600 × 175
|
442 × 600 × 175
|
442 × 600 × 175
|
442 × 600 × 175
|
442 × 600 × 175
|
442 × 600 × 175
|
442 × 600 × 175
|
|
Net Weight (kg)
|
130
|
150
|
170
|
190
|
210
|
230
|
250
|
|
Standard & Certification
|
|||||||
|
Hazardous Materials Classification
|
Class 9
|
Class 9
|
Class 9
|
Class 9
|
Class 9
|
Class 9
|
Class 9
|
|
Transport Testing Requirement
|
UN38.3
|
UN38.3
|
UN38.3
|
UN38.3
|
UN38.3
|
UN38.3
|
UN38.3
|
|
Protection Class
|
Class I
|
Class I
|
Class I
|
Class I
|
Class I
|
Class I
|
Class I
|
|
Certifications
|
IEC 62619, CE, UN38.3
|
IEC 62619, CE, UN38.3
|
IEC 62619, CE, UN38.3
|
IEC 62619, CE, UN38.3
|
IEC 62619, CE, UN38.3
|
IEC 62619, CE, UN38.3
|
IEC 62619, CE, UN38.3
|