Schedule a Professional

Contact Form Demo

MP-BAT-S Series 25.6 ?C 56.3kWh High Voltage Lithium Battery-1318

Designed for commercial and industrial (C&I) applications, the China Moneypro BAT‑S Series is a high‑voltage lithium battery system engineered to provide large‑capacity energy storage, strong safety performance, and flexible expandability. Its modular rack architecture supports stacking of multiple battery packs, making it ideal for projects requiring scalable storage solutions with dependable long‑term operation.

Share your love

Reliable & Scalable Energy Storage

Designed for commercial and industrial (C&I) applications, the China Moneypro BAT‑S Series is a high‑voltage lithium battery system engineered to provide large‑capacity energy storage, strong safety performance, and flexible expandability. Its modular rack architecture supports stacking of multiple battery packs, making it ideal for projects requiring scalable storage solutions with dependable long‑term operation.


High Performance & Flexible Expansion

Modular Design for Capacity Growth

  • Supports 5–11 battery pack stacking per system, enabling customized capacity configurations to match diverse energy demands.

  • Up to 6 battery racks in parallel can be integrated, providing very high total capacity for large installations.

  • Flexible rack design simplifies transportation and installation on‑site.

Benefits:

  • Expand storage capacity as energy requirements grow.

  • Adaptable to different system sizes and project specifications.


Superb Safety & Durability

Engineered for Long‑Lasting Use

  • Uses LFP (Lithium Iron Phosphate) battery cells, known for high cycle stability and inherent safety.

  • Optional aerosol‑based fire suppression system at the pack level enhances fire risk protection and overall system safety.

  • IP20 protection rating ensures reliable resistance against dust and impacts in controlled environments.

Benefits:

  • Safe operation with reduced risk of thermal runaway.

  • Proven durability for commercial environments with high performance expectations.


Smart Control & Monitoring

Intelligent System Management

  • Battery system supports remote monitoring and control for streamlined O&M (operations and maintenance).

  • Automatic reboot after undervoltage events improves resilience and system stability.

  • Modular architecture facilitates simpler upgrades and maintenance compared to fixed‑capacity systems.

Advantages:

  • Reduced onsite intervention for diagnostics and updates.

  • Enhanced reliability with automatic fault recovery.


Why Choose China Moneypro BAT‑S Series?

  • Flexible Capacity: Modular stacking from 25.6 kWh up to 56.3 kWh per rack and more with parallel deployment.

  • Scalable Expansion: Supports multiple racks in parallel for large‑scale storage needs.

  • Safe & Reliable: LFP cells and optional fire suppression for comprehensive protection.

  • Smart Monitoring: Remote O&M and automatic reboot improve system uptime.

  • Modular & Easy to Install: Rack design simplifies transport, installation, and future upgrades.


Key Specifications

Model Usable Energy Nominal Voltage Max. Charge / Discharge Current Protection
BAT‑25.6 ~25 kWh 256 V ~100 / 110 A IP20
BAT‑30.7 ~30 kWh 307.2 V ~100 / 110 A IP20
BAT‑35.8 ~35 kWh 358.4 V ~100 / 110 A IP20
BAT‑40.9 ~40 kWh 409.6 V ~100 / 110 A IP20
BAT‑46.0 ~45 kWh 460.8 V ~100 / 110 A IP20
BAT‑51.2 ~50 kWh 512 V ~100 / 110 A IP20
BAT‑56.3 ~55 kWh 563.2 V ~100 / 110 A IP20
*Values are rounded nominal figures for typical configurations.

Typical Applications

  • Commercial Solar + Storage: Provides substantial energy capacity for business peak load management and self‑consumption optimization.

  • Industrial Backup Power: Ensures reliable power support during grid interruptions for critical loads.

  • Energy Cost Optimization: Helps reduce peak demand charges and manage energy usage proactively.

  • Large‑Scale Hybrid Systems: Works with high‑voltage hybrid inverters for flexible PV + storage integration.


FAQ – Common Questions

Q1: What capacity options are available in the BAT‑S Series?
The series offers modular battery packs from ~25.6 kWh up to ~56.3 kWh, which can be combined across multiple racks for larger systems.

Q2: What type of battery cells are used?
It uses LFP (Lithium Iron Phosphate) cells known for high safety and cycle stability.

Q3: Can multiple BAT‑S units be connected together?
Yes — up to 6 battery racks can be paralleled to achieve very high storage capacities.

Q4: Is the system suitable for commercial energy storage use?
Absolutely — it’s designed specifically for C&I applications such as peak shaving, backup power, and load management.

Q5: How is maintenance and monitoring handled?
The system supports remote monitoring and control, along with automatic fault recovery to ease O&M.


Specifications

Technical Data
BAT25
BAT30
BAT35
BAT40
BAT45
BAT50
BAT56
Input
Nominal Voltage (V)
204.8
204.8
204.8
204.8
204.8
204.8
204.8
Operating Voltage Range (V)
180 ~ 228
180 ~ 228
180 ~ 228
180 ~ 228
180 ~ 228
180 ~ 228
180 ~ 228
Nominal Capacity (Ah)
125
150
175
200
225
250
275
Nominal Energy (kWh)
25.6
30.7
35.8
41.0
46.1
51.2
56.3
Usable Energy (90% DOD, kWh)
23.0
27.6
32.2
36.9
41.5
46.1
50.7
Max. Charge / Discharge Current (A)
50 / 50
50 / 50
50 / 50
50 / 50
50 / 50
50 / 50
50 / 50
Max. Charge / Discharge Power (kW)
10.24 / 10.24
10.24 / 10.24
10.24 / 10.24
10.24 / 10.24
10.24 / 10.24
10.24 / 10.24
10.24 / 10.24
Depth of Discharge
90%
90%
90%
90%
90%
90%
90%
Efficiency
Battery Roundtrip Efficiency (25°C)
95%
95%
95%
95%
95%
95%
95%
Cycle Life & Warranty
Cycle Life (90% DOD, 25°C)
> 6000 cycles
> 6000 cycles
> 6000 cycles
> 6000 cycles
> 6000 cycles
> 6000 cycles
> 6000 cycles
Warranty
10 Years
10 Years
10 Years
10 Years
10 Years
10 Years
10 Years
Scalability
2 ~ 8 modules in parallel
2 ~ 8 modules in parallel
2 ~ 8 modules in parallel
2 ~ 8 modules in parallel
2 ~ 8 modules in parallel
2 ~ 8 modules in parallel
2 ~ 8 modules in parallel
Environmental Requirements
Operating Temperature – Charge (°C)
0 ~ +55
0 ~ +55
0 ~ +55
0 ~ +55
0 ~ +55
0 ~ +55
0 ~ +55
Operating Temperature – Discharge (°C)
-20 ~ +55
-20 ~ +55
-20 ~ +55
-20 ~ +55
-20 ~ +55
-20 ~ +55
-20 ~ +55
Storage Temperature – 1~3 months (°C)
-20 ~ +45
-20 ~ +45
-20 ~ +45
-20 ~ +45
-20 ~ +45
-20 ~ +45
-20 ~ +45
Storage Temperature – 3~6 months (°C)
-20 ~ +35
-20 ~ +35
-20 ~ +35
-20 ~ +35
-20 ~ +35
-20 ~ +35
-20 ~ +35
Storage Temperature – 6~12 months (°C)
-20 ~ +30
-20 ~ +30
-20 ~ +30
-20 ~ +30
-20 ~ +30
-20 ~ +30
-20 ~ +30
Relative Humidity
5 ~ 95% RH (non-condensing)
5 ~ 95% RH (non-condensing)
5 ~ 95% RH (non-condensing)
5 ~ 95% RH (non-condensing)
5 ~ 95% RH (non-condensing)
5 ~ 95% RH (non-condensing)
5 ~ 95% RH (non-condensing)
Max. Operating Altitude (m)
< 3000
< 3000
< 3000
< 3000
< 3000
< 3000
< 3000
Cooling Method
Natural cooling
Natural cooling
Natural cooling
Natural cooling
Natural cooling
Natural cooling
Natural cooling
Environment
Indoor
Indoor
Indoor
Indoor
Indoor
Indoor
Indoor
Ingress Protection Rating
IP20
IP20
IP20
IP20
IP20
IP20
IP20
Installation Type
Rack mounting
Rack mounting
Rack mounting
Rack mounting
Rack mounting
Rack mounting
Rack mounting
Communication & Interface
Display
LED Indicators
LED Indicators
LED Indicators
LED Indicators
LED Indicators
LED Indicators
LED Indicators
Communication Interfaces
CAN / RS485
CAN / RS485
CAN / RS485
CAN / RS485
CAN / RS485
CAN / RS485
CAN / RS485
Communication Protocol
Modbus-RTU
Modbus-RTU
Modbus-RTU
Modbus-RTU
Modbus-RTU
Modbus-RTU
Modbus-RTU
Protection & Safety
Protection Features
Overcharge/Over-discharge Protection, Overcurrent Protection, Short Circuit Protection, Over-temperature Protection, Insulation Detection
Overcharge/Over-discharge Protection, Overcurrent Protection, Short Circuit Protection, Over-temperature Protection, Insulation Detection
Overcharge/Over-discharge Protection, Overcurrent Protection, Short Circuit Protection, Over-temperature Protection, Insulation Detection
Overcharge/Over-discharge Protection, Overcurrent Protection, Short Circuit Protection, Over-temperature Protection, Insulation Detection
Overcharge/Over-discharge Protection, Overcurrent Protection, Short Circuit Protection, Over-temperature Protection, Insulation Detection
Overcharge/Over-discharge Protection, Overcurrent Protection, Short Circuit Protection, Over-temperature Protection, Insulation Detection
Overcharge/Over-discharge Protection, Overcurrent Protection, Short Circuit Protection, Over-temperature Protection, Insulation Detection
Surge Protection
Integrated
Integrated
Integrated
Integrated
Integrated
Integrated
Integrated
Mechanical Parameters
Dimensions (W × H × D mm)
442 × 600 × 175
442 × 600 × 175
442 × 600 × 175
442 × 600 × 175
442 × 600 × 175
442 × 600 × 175
442 × 600 × 175
Net Weight (kg)
130
150
170
190
210
230
250
Standard & Certification
Hazardous Materials Classification
Class 9
Class 9
Class 9
Class 9
Class 9
Class 9
Class 9
Transport Testing Requirement
UN38.3
UN38.3
UN38.3
UN38.3
UN38.3
UN38.3
UN38.3
Protection Class
Class I
Class I
Class I
Class I
Class I
Class I
Class I
Certifications
IEC 62619, CE, UN38.3
IEC 62619, CE, UN38.3
IEC 62619, CE, UN38.3
IEC 62619, CE, UN38.3
IEC 62619, CE, UN38.3
IEC 62619, CE, UN38.3
IEC 62619, CE, UN38.3